|
| /*===================================================================*/
/* NRDF D1769 Data No.41 */
/*===================================================================*/
/* Bibliography */
/*===================================================================*/
\\BIB,41;
D#=D1769;
TITLE=/ Double-differential cross sections for the neutron
production from heavy-ion reactions at energies E/A = 290-600
MeV /;
PURPOSE=/ Systematic measurements of neutron-production cross
sections from C, Ne, and Ar projectiles having E/A = 290-600
MeV on C, Cu, and Pb targets. /;
ATH=(Y.IWATA'1', T.MURAKAMI'1', H.SATO'2', H.IWASE'2', T.NAKAMURA'2',
T.KUROSAWA'2', L.HEILBRONN'3', R.M.RONNINGEN'4', K.IEKI'5',
Y.TOZAWA'5', K.NIITA'6');
INST-ATH=(2JPNIRS'1', 2JPNTOH'2', 1USABRK'3', 1USAMSU'4', 2JPNRIK'5',
2JPNJPN'6');
/* '1' Department of Accelerator Physics and Engineering */
/* '2' Cyclotron and Radioisotope Center */
/* '4' National Superconducting Cyclotron Laboratory */
/* '5' Department of Physics */
/* '6' Research Organization for Information Science and
Technology, Tokai, Naka, Ibaraki */
REF=PR/C;
VLP=64(2001)054609;
RCTS=(C(12C,N)X, CU(12C,N)X, PB(12C,N)X, C(20NE,N)X, CU(20NE,N)X,
PB(20NE,N)X, C(40AR,N)X, CU(40AR,N)X, PB(40AR,N)X);
PHQS=(ENGY-SPEC, ANGL-DSTRN, XSECTN, TOT-XSECTN, MLT);
/*===================================================================*/
/* Experimental Conditions */
/*===================================================================*/
\\EXP,41;
/* 2002-08-01 : Compiled, Am + Sr + On */
/* 2006-07-25 : Altered, On. Heading of data error corrected.
Systematic uncertainties added. */
RTY=HEAVY-ION-RCT;
ENR=NAT;
CHM=ELM;
PHYS-FORM=SLD;
BAC=X;
POL-TGT=0%;
ALGN-TGT=0%;
ACC=SYN'7';
/* '7' Heavy Ion Medical Accelerator in Chiba (HIMAC) facility
INST-ACC=2JPNIRS;
BEAM-INTNSTY=XMA'8';
/* '8' A few times 10e4-10e5 particles per pulse */
POL-PRJ=0%;
DET-PARTCL=N;
COINC=NO;
ANT-COINC=NO;
DET-SYS=(SCT'9',SCT'10',TOF);
/* '9' NE102A plastic scintillator */
/* '10' NE213 liquid scintillator */
ERS-DET=XKEV'11';
/* '11' The energy resolutions are shown in Table I in reference.
/* Experimental Method:
- Time-of-flight
RCT=PB(12C,N)X;
PHQ=ENGY-SPEC;
THK-TGT=9080MG/CM**2;
INC-ENGY-LAB=400.0MEV/A;
ANL=X'133';
/* '133' Moving-source model, QMD and HIC */
/*===================================================================*/
/* Descriptive Parameters */
/*===================================================================*/
\\DATA,41;
SYS-ERR=10%'12';
/* '12' Uncertainty in detection efficiency */
INC-ENGY-LAB=400.0MEV/A;
SYS-ERR=4.6%'134';
/* '134' Uncertainty in target thickness */
THTL=60DEG;
/*===================================================================*/
/* Data Table */
/*===================================================================*/
\DATA;
ENGY-EMT-LAB DSIGMA/DOMEGA/DE DELTA-DSIGMA/DOMEGA/DE'135'
(MEV) (MB/SR/MEV) (MB/SR/MEV)
5 478 +-12
6 297 +-9
7 224 +-8
8 188 +-7
9 138 +-6
10 115 +-5
15 54.6 +-1.3
25 33.5 +-1.1
35 24.0 +-1.0
45 18.1 +-1.0
55 14.3 +-0.8
65 14.5 +-0.8
75 11.5 +-0.8
85 10.9 +-0.7
95 7.47 +-0.77
105 9.06 +-0.70
125 8.94 +-0.51
145 4.19 +-0.39
165 4.30 +-0.30
185 2.26 +-0.27
205 2.26 +-0.24
235 1.89 +-0.19
265 0.981 +-0.143
295 0.528 +-0.110
325 0.377 +-0.086
365 0.226 +-0.069
405 0.113 +-0.032
465 3.77e-02 +-3.62e-02
525 3.77e-02 +-2.00e-02
605 2.83e-02 +-1.20e-02
725 0.00e+00 +-1.54e-02
885 1.42e-02 +-9.94e-03
1085 1.13e-02 +-1.45e-02
1285 2.26e-02 +-1.10e-02
1485 2.26e-02 +-9.11e-03
1685 1.13e-02 +-1.04e-02
1885 0.00e+00 +-5.18e-03
\END;
/*===================================================================*/
|