/* NRDF D1769 Data No.40 */
/*===================================================================*/
/* Bibliography */
/*===================================================================*/
\\BIB,40;
D#=D1769;
TITLE=/ Double-differential cross sections for the neutron
production from heavy-ion reactions at energies E/A = 290-600
MeV /;
PURPOSE=/ Systematic measurements of neutron-production cross
sections from C, Ne, and Ar projectiles having E/A = 290-600
MeV on C, Cu, and Pb targets. /;
ATH=(Y.IWATA'1', T.MURAKAMI'1', H.SATO'2', H.IWASE'2', T.NAKAMURA'2',
T.KUROSAWA'2', L.HEILBRONN'3', R.M.RONNINGEN'4', K.IEKI'5',
Y.TOZAWA'5', K.NIITA'6');
INST-ATH=(2JPNIRS'1', 2JPNTOH'2', 1USABRK'3', 1USAMSU'4', 2JPNRIK'5',
2JPNJPN'6');
/* '1' Department of Accelerator Physics and Engineering */
/* '2' Cyclotron and Radioisotope Center */
/* '4' National Superconducting Cyclotron Laboratory */
/* '5' Department of Physics */
/* '6' Research Organization for Information Science and
Technology, Tokai, Naka, Ibaraki */
REF=PR/C;
VLP=64(2001)054609;
RCTS=(C(12C,N)X, CU(12C,N)X, PB(12C,N)X, C(20NE,N)X, CU(20NE,N)X,
PB(20NE,N)X, C(40AR,N)X, CU(40AR,N)X, PB(40AR,N)X);
PHQS=(ENGY-SPEC, ANGL-DSTRN, XSECTN, TOT-XSECTN, MLT);
/*===================================================================*/
/* Experimental Conditions */
/*===================================================================*/
\\EXP,40;
/* 2002-08-01 : Compiled, Am + Sr + On */
/* 2006-07-25 : Altered, On. Heading of data error corrected.
Systematic uncertainties added. */
RTY=HEAVY-ION-RCT;
ENR=NAT;
CHM=ELM;
PHYS-FORM=SLD;
BAC=X;
POL-TGT=0%;
ALGN-TGT=0%;
ACC=SYN'7';
/* '7' Heavy Ion Medical Accelerator in Chiba (HIMAC) facility
INST-ACC=2JPNIRS;
BEAM-INTNSTY=XMA'8';
/* '8' A few times 10e4-10e5 particles per pulse */
POL-PRJ=0%;
DET-PARTCL=N;
COINC=NO;
ANT-COINC=NO;
DET-SYS=(SCT'9',SCT'10',TOF);
/* '9' NE102A plastic scintillator */
/* '10' NE213 liquid scintillator */
ERS-DET=XKEV'11';
/* '11' The energy resolutions are shown in Table I in reference.
/* Experimental Method:
- Time-of-flight
RCT=PB(12C,N)X;
PHQ=ENGY-SPEC;
THK-TGT=9080MG/CM**2;
INC-ENGY-LAB=400.0MEV/A;
ANL=X'130';
/* '130' Moving-source model, QMD and HIC */
/*===================================================================*/
/* Descriptive Parameters */
/*===================================================================*/
\\DATA,40;
SYS-ERR=10%'12';
/* '12' Uncertainty in detection efficiency */
INC-ENGY-LAB=400.0MEV/A;
SYS-ERR=4.6%'131';
/* '131' Uncertainty in target thickness */
THTL=40DEG;
/*===================================================================*/
/* Data Table */
/*===================================================================*/
\DATA;
ENGY-EMT-LAB DSIGMA/DOMEGA/DE DELTA-DSIGMA/DOMEGA/DE'132'
(MEV) (MB/SR/MEV) (MB/SR/MEV)
5 327 +-15
6 256 +-12
7 203 +-10
8 150 +-9
9 135 +-8
10 103 +-8
15 51.2 +-1.8
25 35.6 +-1.5
35 28.0 +-1.4
45 18.3 +-1.3
55 18.8 +-1.4
65 12.7 +-1.3
75 17.4 +-1.4
85 13.8 +-1.3
95 11.5 +-1.1
105 12.1 +-1.2
125 13.1 +-0.8
145 9.27 +-0.64
165 7.21 +-0.61
185 3.68 +-0.48
205 5.45 +-0.45
235 4.51 +-0.40
265 3.43 +-0.31
295 2.36 +-0.31
325 1.86 +-0.25
365 1.25 +-0.18
405 1.03 +-0.13
465 0.589 +-0.086
525 0.294 +-0.088
605 0.110 +-0.041
725 9.81e-02 +-3.01e-02
885 1.84e-02 +-1.10e-02
1085 1.47e-02 +-6.69e-03
1285 1.47e-02 +-7.47e-03
1485 0.00e+00 +-6.70e-03
1685 0.00e+00 +-1.23e-02
1885 0.00e+00 +-7.93e-03
\END;
/*===================================================================*/
|