/* NRDF D1251 Data No.4 */
/*===================================================================*/
/* Bibliography */
/*===================================================================*/
\\BIB,4;
D#=D1251;
TITLE=/ Nuclear reactions of Ti, Fe, Co, Ni, Cu, and Zn by 500-MeV
protons /;
ATH=(Y.ASANO'1', S.MORI'1', M.SAKANO'1', K.KATOH'2', K.KONDO'2',
M.NOGUCHI'2');
INST-ATH=(2JPNTSU'1', 2JPNKEK'2');
/* '1' Institute of Applied Physics */
REF=JPJ;
VLP=60(1991)107;
RCTS=(TI(P,X)X, FE(P,X)X, 59CO(P,X)X, NI(P,X)X, CU(P,X)X, ZN(P,X)X);
PHQS=XSECTN;
/*===================================================================*/
/* Experimental Conditions */
/*===================================================================*/
\\EXP,4;
/* 2007-01-18 : Converted, N.Otuka. Converted to EXFOR E1251 */
/* Related references
- T.Asano et al., PR/C, 28(1983)1718.
(Cross section ratio of present data to this reference (at 12 GeV)
discussed). See also NRDF D1243.
PHQ=XSECTN;
/* Additional results shown but not compiled
- Mass distribution (Shown in Fig.1 and 3 in reference)
- Charge distribution (Shown in Fig.2 in reference)
ENR=NAT'3';
/* '3' noen */
CHM=ELM;
PHYS-FORM=SLD;
POL-TGT=0%;
ALGN-TGT=0%;
ACC=SYN;
INST-ACC=2JPNKEK;
INC-ENGY-LAB-RANGE=500MEV;
POL-PRJ=0%;
DET-PARTCL=GAMMA'4';
/* '4' Decay data not given */
COINC=NO;
ANT-COINC=NO;
DET-SYS=GE(LI)'5';
/* '5' To measure gamma rays */
/* Experimental Method:
- Stacked target irradiation (Stack of thin metal foils of 14
elements)
- Activation (Irradiated for 3 min)
- Gamma ray spectrometry (Measured about 14 spectra during 7
months)
/* By authors: Measurements of short-lived nuclides with lifetimes
shorter than a few hours could not be made. */
RCT=FE(P,X)X'15';
/* '15' See DATA section for atomic number (Z) and mass number
(A) of products */
THK-TGT=7.51MG/CM**2;
/*===================================================================*/
/* Descriptive Parameters */
/*===================================================================*/
\\DATA,4;
INC-ENGY-LAB=500MEV;
TOT-ERR=X%'6';
/* '6' Uncertainties in detection efficiency of gamma rays and
statistical uncertainty for photo-yield (Uncertainties in beam
intensity calibration are not included.) */
SYS-ERR=(10%'7',15%'8');
/* '7' Uncertainty in beam intensity calibration */
/* '8' Maximum uncertainty in detection efficiency (15% below 200
keV, 10% at 200-400 keV, 5% above 400 keV) */
/*===================================================================*/
/* Data Table */
/*===================================================================*/
\DATA;
Z A SIGMA'16' DELTA-SIGMA'16'
(NODIM) (NODIM) (MB) (MB)
11. 22 0.29 +-0.019
11. 24 0.36 +-0.02
19. 43 0.61 +-0.03
21. 43 1.48 +-0.21
21. 47 2.39 +-0.36
23. 48 13.6 +-0.74
24. 51 36.0 +-1.8
25. 56 1.30 +-0.60
27. 55 0.29 +-0.03
27. 56 0.67 +-0.10
27. 57 0.16 +-0.03
\END;
/*===================================================================*/
|