/* NRDF D1243 Data No.4 */
/*===================================================================*/
/* Bibliography */
/*===================================================================*/
\\BIB,4;
D#=D1243;
TITLE=/ Target dependence of charge distributions in spallation
reactions of medium-mass nuclei with 12 GeV protons /;
ATH=(T.ASANO'1', Y.ASANO'1', Y.IGUCHI'1', H.KUDO'1', S.MORI'1',
M.NOGUCHI'1', Y.TAKADA'1', H.HIRABAYASHI'2', H.IKEDA'2',
K.KATOH'2', K.KONDO'2', M.TAKASAKI'2', T.TOMINAKA'2',
A.YAMAMOTO'2');
INST-ATH=(2JPNTSU'1', 2JPNKEK'2');
/* '1' Institute of Applied Physics */
REF=PR/C;
VLP=28(1983)1718;
RCTS=(TI(P,X)X, FE(P,X)X, 59CO(P,X)X, NI(P,X)X, CU(P,X)X, ZN(P,X)X);
PHQS=XSECTN;
/*===================================================================*/
/* Experimental Conditions */
/*===================================================================*/
\\EXP,4;
/* 2007-01-18 : Converted, N.Otuka. Converted to EXFOR E1243 */
/* Related references
- H.Hirabayashi et al., JPJ, 51(1982)3098.
Reference for monitor. See also NRDF D0962 DATA 1.
PHQ=XSECTN;
/* Additional results shown but not compiled
- Charge distribution (Shown in Fig.2 in reference)
- Mass distribution (Shown in Fig.3 in reference)
ENR=NAT;
CHM=ELM;
PHYS-FORM=SLD;
POL-TGT=0%;
ALGN-TGT=0%;
ACC=SYN;
INST-ACC=2JPNKEK;
INC-ENGY-LAB-RANGE=12GEV;
POL-PRJ=0%;
DET-PARTCL=GAMMA'3';
/* '3' Decay data not given */
COINC=NO;
ANT-COINC=NO;
DET-SYS=GE(LI)'4';
/* '4' For gamma-ray spectroscopy */
/* Experimental Method:
- Stacked target irradiation (Total thickness of 0.5 g/cm2)
- Activation (Irradiation for 10 min)
- Gamma ray spectrometry (Performed during 3 months starting
about a few hours after the end of irradiation)
/* By authors: Detection of nuclides with lifetimes shorter than about
one hour are precluded. */
RCT=FE(P,X)X'17';
/* '17' See DATA section for atomic number (Z) and mass number
(A) of products */
THK-TGT=7.52MG/CM**2;
MONTR-RCT=/ 27AL(P,X)24NA /;
/*===================================================================*/
/* Descriptive Parameters */
/*===================================================================*/
\\DATA,4;
INC-ENGY-LAB=12GEV;
TOT-ERR=X%'5';
/* '5' Uncertainty in detection efficiency of gamma rays and
statistical errors for photopeak yields (Uncertainty in beam
intensity calibration is not included.) */
SYS-ERR=(10%'6',15%'7');
/* '6' Uncertainty in beam intensity calibration */
/* '7' Maximum uncertainty in detection efficiency (15% below 200
keV, 5% above 400 keV) */
DATA1=8.1MB'18';
/* '18' Used for calibration of the beam intensity monitoring
system */
DELTA-DATA1=0.9MB;
/*===================================================================*/
/* Data Table */
/*===================================================================*/
\DATA;
Z A SIGMA',19' DELTA-SIGMA''
(NODIM) (NODIM) (MB) (MB)
11. 22 2.35 +-0.19
11. 24 3.34 +-0.19
12. 28 0.40 +-0.03
18. 41 0.51 +-0.03
19. 43 0.76 +-0.04
21. 43 1.74 +-0.11
21. 47 1.98 +-0.30
23. 48 8.00 +-0.41
24. 51 21.5 +-1.1
25. 56 0.79 +-0.05
27. 56 0.53 +-0.04
27. 57 0.32 +-0.05
\END;
/*===================================================================*/
|