|
| /*===================================================================*/
/* NRDF D1769 Data No.38 */
/*===================================================================*/
/* Bibliography */
/*===================================================================*/
\\BIB,38;
D#=D1769;
TITLE=/ Double-differential cross sections for the neutron
production from heavy-ion reactions at energies E/A = 290-600
MeV /;
PURPOSE=/ Systematic measurements of neutron-production cross
sections from C, Ne, and Ar projectiles having E/A = 290-600
MeV on C, Cu, and Pb targets. /;
ATH=(Y.IWATA'1', T.MURAKAMI'1', H.SATO'2', H.IWASE'2', T.NAKAMURA'2',
T.KUROSAWA'2', L.HEILBRONN'3', R.M.RONNINGEN'4', K.IEKI'5',
Y.TOZAWA'5', K.NIITA'6');
INST-ATH=(2JPNIRS'1', 2JPNTOH'2', 1USABRK'3', 1USAMSU'4', 2JPNRIK'5',
2JPNJPN'6');
/* '1' Department of Accelerator Physics and Engineering */
/* '2' Cyclotron and Radioisotope Center */
/* '4' National Superconducting Cyclotron Laboratory */
/* '5' Department of Physics */
/* '6' Research Organization for Information Science and
Technology, Tokai, Naka, Ibaraki */
REF=PR/C;
VLP=64(2001)054609;
RCTS=(C(12C,N)X, CU(12C,N)X, PB(12C,N)X, C(20NE,N)X, CU(20NE,N)X,
PB(20NE,N)X, C(40AR,N)X, CU(40AR,N)X, PB(40AR,N)X);
PHQS=(ENGY-SPEC, ANGL-DSTRN, XSECTN, TOT-XSECTN, MLT);
/*===================================================================*/
/* Experimental Conditions */
/*===================================================================*/
\\EXP,38;
/* 2002-08-01 : Compiled, Am + Sr + On */
/* 2006-07-25 : Altered, On. Heading of data error corrected.
Systematic uncertainties added. */
RTY=HEAVY-ION-RCT;
ENR=NAT;
CHM=ELM;
PHYS-FORM=SLD;
BAC=X;
POL-TGT=0%;
ALGN-TGT=0%;
ACC=SYN'7';
/* '7' Heavy Ion Medical Accelerator in Chiba (HIMAC) facility
INST-ACC=2JPNIRS;
BEAM-INTNSTY=XMA'8';
/* '8' A few times 10e4-10e5 particles per pulse */
POL-PRJ=0%;
DET-PARTCL=N;
COINC=NO;
ANT-COINC=NO;
DET-SYS=(SCT'9',SCT'10',TOF);
/* '9' NE102A plastic scintillator */
/* '10' NE213 liquid scintillator */
ERS-DET=XKEV'11';
/* '11' The energy resolutions are shown in Table I in reference.
/* Experimental Method:
- Time-of-flight
RCT=PB(12C,N)X;
PHQ=ENGY-SPEC;
THK-TGT=9080MG/CM**2;
INC-ENGY-LAB=400.0MEV/A;
ANL=X'124';
/* '124' Moving-source model, QMD and HIC */
/*===================================================================*/
/* Descriptive Parameters */
/*===================================================================*/
\\DATA,38;
SYS-ERR=10%'12';
/* '12' Uncertainty in detection efficiency */
INC-ENGY-LAB=400.0MEV/A;
SYS-ERR=4.6%'125';
/* '125' Uncertainty in target thickness */
THTL=20DEG;
/*===================================================================*/
/* Data Table */
/*===================================================================*/
\DATA;
ENGY-EMT-LAB DSIGMA/DOMEGA/DE DELTA-DSIGMA/DOMEGA/DE'126'
(MEV) (MB/SR/MEV) (MB/SR/MEV)
15 85.8 +-4.3
25 43.1 +-3.1
35 33.8 +-2.6
45 29.0 +-2.3
55 23.4 +-2.0
65 20.1 +-2.0
75 17.5 +-2.1
85 14.9 +-2.1
95 14.9 +-1.8
105 13.4 +-2.2
125 12.1 +-1.9
145 10.0 +-1.5
165 7.98 +-1.11
185 9.47 +-1.14
205 9.65 +-1.12
235 10.5 +-0.8
265 8.54 +-0.69
295 7.55 +-0.68
325 6.06 +-0.65
365 5.01 +-0.46
405 2.23 +-0.29
465 2.78 +-0.24
525 0.990 +-0.193
605 0.789 +-0.112
725 0.217 +-0.042
885 4.64e-02 +-2.59e-02
1085 0.00e+00 +-1.60e-02
1485 0.00e+00 +-4.91e-03
1685 0.00e+00 +-4.27e-03
1885 0.00e+00 +-3.11e-03
\END;
/*===================================================================*/
|