|
| /*===================================================================*/
/* NRDF D1769 Data No.35 */
/*===================================================================*/
/* Bibliography */
/*===================================================================*/
\\BIB,35;
D#=D1769;
TITLE=/ Double-differential cross sections for the neutron
production from heavy-ion reactions at energies E/A = 290-600
MeV /;
PURPOSE=/ Systematic measurements of neutron-production cross
sections from C, Ne, and Ar projectiles having E/A = 290-600
MeV on C, Cu, and Pb targets. /;
ATH=(Y.IWATA'1', T.MURAKAMI'1', H.SATO'2', H.IWASE'2', T.NAKAMURA'2',
T.KUROSAWA'2', L.HEILBRONN'3', R.M.RONNINGEN'4', K.IEKI'5',
Y.TOZAWA'5', K.NIITA'6');
INST-ATH=(2JPNIRS'1', 2JPNTOH'2', 1USABRK'3', 1USAMSU'4', 2JPNRIK'5',
2JPNJPN'6');
/* '1' Department of Accelerator Physics and Engineering */
/* '2' Cyclotron and Radioisotope Center */
/* '4' National Superconducting Cyclotron Laboratory */
/* '5' Department of Physics */
/* '6' Research Organization for Information Science and
Technology, Tokai, Naka, Ibaraki */
REF=PR/C;
VLP=64(2001)054609;
RCTS=(C(12C,N)X, CU(12C,N)X, PB(12C,N)X, C(20NE,N)X, CU(20NE,N)X,
PB(20NE,N)X, C(40AR,N)X, CU(40AR,N)X, PB(40AR,N)X);
PHQS=(ENGY-SPEC, ANGL-DSTRN, XSECTN, TOT-XSECTN, MLT);
/*===================================================================*/
/* Experimental Conditions */
/*===================================================================*/
\\EXP,35;
/* 2002-08-01 : Compiled, Am + Sr + On */
/* 2006-07-25 : Altered, On. Heading of data error corrected.
Systematic uncertainties added. */
RTY=HEAVY-ION-RCT;
ENR=NAT;
CHM=ELM;
PHYS-FORM=SLD;
BAC=X;
POL-TGT=0%;
ALGN-TGT=0%;
ACC=SYN'7';
/* '7' Heavy Ion Medical Accelerator in Chiba (HIMAC) facility
INST-ACC=2JPNIRS;
BEAM-INTNSTY=XMA'8';
/* '8' A few times 10e4-10e5 particles per pulse */
POL-PRJ=0%;
DET-PARTCL=N;
COINC=NO;
ANT-COINC=NO;
DET-SYS=(SCT'9',SCT'10',TOF);
/* '9' NE102A plastic scintillator */
/* '10' NE213 liquid scintillator */
ERS-DET=XKEV'11';
/* '11' The energy resolutions are shown in Table I in reference.
/* Experimental Method:
- Time-of-flight
RCT=CU(12C,N)X;
PHQ=ENGY-SPEC;
THK-TGT=13400MG/CM**2;
INC-ENGY-LAB=400.0MEV/A;
ANL=X'115';
/* '115' Moving-source model, QMD and HIC */
/*===================================================================*/
/* Descriptive Parameters */
/*===================================================================*/
\\DATA,35;
SYS-ERR=10%'12';
/* '12' Uncertainty in detection efficiency */
INC-ENGY-LAB=400.0MEV/A;
SYS-ERR=2.5%'116';
/* '116' Uncertainty in target thickness */
THTL=80DEG;
/*===================================================================*/
/* Data Table */
/*===================================================================*/
\DATA;
ENGY-EMT-LAB DSIGMA/DOMEGA/DE DELTA-DSIGMA/DOMEGA/DE'117'
(MEV) (MB/SR/MEV) (MB/SR/MEV)
5 49.6 +-2.2
6 30.2 +-1.7
7 23.6 +-1.4
8 19.1 +-1.3
9 15.6 +-1.1
10 13.9 +-1.0
15 6.80 +-0.26
25 4.89 +-0.22
35 4.09 +-0.20
45 3.43 +-0.20
55 2.60 +-0.18
65 2.22 +-0.18
75 2.05 +-0.16
85 1.73 +-0.15
95 1.42 +-0.14
105 1.04 +-0.13
125 0.988 +-0.086
145 0.520 +-0.070
165 0.347 +-0.058
185 0.347 +-0.049
205 0.208 +-0.049
235 0.104 +-0.029
265 6.93e-02 +-2.33e-02
295 4.62e-02 +-1.40e-02
325 4.62e-02 +-1.38e-02
365 2.60e-02 +-1.27e-02
405 8.67e-03 +-1.15e-02
465 0.00e+00 +-7.83e-03
525 1.16e-02 +-5.17e-03
605 4.33e-03 +-2.90e-03
725 8.67e-03 +-3.03e-03
885 1.08e-02 +-3.36e-03
1085 6.93e-03 +-2.56e-03
1285 1.04e-02 +-3.03e-03
1485 6.93e-03 +-3.09e-03
1685 5.20e-03 +-3.10e-03
1885 0.00e+00 +-6.58e-04
\END;
/*===================================================================*/
|