/* NRDF D1769 Data No.34 */
/*===================================================================*/
/* Bibliography */
/*===================================================================*/
\\BIB,34;
D#=D1769;
TITLE=/ Double-differential cross sections for the neutron
production from heavy-ion reactions at energies E/A = 290-600
MeV /;
PURPOSE=/ Systematic measurements of neutron-production cross
sections from C, Ne, and Ar projectiles having E/A = 290-600
MeV on C, Cu, and Pb targets. /;
ATH=(Y.IWATA'1', T.MURAKAMI'1', H.SATO'2', H.IWASE'2', T.NAKAMURA'2',
T.KUROSAWA'2', L.HEILBRONN'3', R.M.RONNINGEN'4', K.IEKI'5',
Y.TOZAWA'5', K.NIITA'6');
INST-ATH=(2JPNIRS'1', 2JPNTOH'2', 1USABRK'3', 1USAMSU'4', 2JPNRIK'5',
2JPNJPN'6');
/* '1' Department of Accelerator Physics and Engineering */
/* '2' Cyclotron and Radioisotope Center */
/* '4' National Superconducting Cyclotron Laboratory */
/* '5' Department of Physics */
/* '6' Research Organization for Information Science and
Technology, Tokai, Naka, Ibaraki */
REF=PR/C;
VLP=64(2001)054609;
RCTS=(C(12C,N)X, CU(12C,N)X, PB(12C,N)X, C(20NE,N)X, CU(20NE,N)X,
PB(20NE,N)X, C(40AR,N)X, CU(40AR,N)X, PB(40AR,N)X);
PHQS=(ENGY-SPEC, ANGL-DSTRN, XSECTN, TOT-XSECTN, MLT);
/*===================================================================*/
/* Experimental Conditions */
/*===================================================================*/
\\EXP,34;
/* 2002-08-01 : Compiled, Am + Sr + On */
/* 2006-07-25 : Altered, On. Heading of data error corrected.
Systematic uncertainties added. */
RTY=HEAVY-ION-RCT;
ENR=NAT;
CHM=ELM;
PHYS-FORM=SLD;
BAC=X;
POL-TGT=0%;
ALGN-TGT=0%;
ACC=SYN'7';
/* '7' Heavy Ion Medical Accelerator in Chiba (HIMAC) facility
INST-ACC=2JPNIRS;
BEAM-INTNSTY=XMA'8';
/* '8' A few times 10e4-10e5 particles per pulse */
POL-PRJ=0%;
DET-PARTCL=N;
COINC=NO;
ANT-COINC=NO;
DET-SYS=(SCT'9',SCT'10',TOF);
/* '9' NE102A plastic scintillator */
/* '10' NE213 liquid scintillator */
ERS-DET=XKEV'11';
/* '11' The energy resolutions are shown in Table I in reference.
/* Experimental Method:
- Time-of-flight
RCT=CU(12C,N)X;
PHQ=ENGY-SPEC;
THK-TGT=13400MG/CM**2;
INC-ENGY-LAB=400.0MEV/A;
ANL=X'112';
/* '112' Moving-source model, QMD and HIC */
/*===================================================================*/
/* Descriptive Parameters */
/*===================================================================*/
\\DATA,34;
SYS-ERR=10%'12';
/* '12' Uncertainty in detection efficiency */
INC-ENGY-LAB=400.0MEV/A;
SYS-ERR=2.5%'113';
/* '113' Uncertainty in target thickness */
THTL=60DEG;
/*===================================================================*/
/* Data Table */
/*===================================================================*/
\DATA;
ENGY-EMT-LAB DSIGMA/DOMEGA/DE DELTA-DSIGMA/DOMEGA/DE'114'
(MEV) (MB/SR/MEV) (MB/SR/MEV)
5 75.5 +-3.3
6 46.4 +-2.5
7 40.8 +-2.1
8 26.7 +-2.0
9 21.6 +-1.8
10 22.0 +-1.6
15 10.6 +-0.4
25 7.98 +-0.37
35 6.52 +-0.37
45 4.97 +-0.33
55 4.69 +-0.34
65 4.64 +-0.35
75 4.18 +-0.28
85 3.99 +-0.29
95 3.71 +-0.31
105 3.19 +-0.27
125 2.77 +-0.19
145 2.06 +-0.15
165 1.45 +-0.13
185 1.10 +-0.10
205 0.938 +-0.095
235 0.672 +-0.070
265 0.297 +-0.046
295 0.250 +-0.044
325 0.156 +-0.031
365 8.21e-02 +-2.50e-02
405 2.35e-02 +-1.91e-02
465 2.35e-02 +-9.50e-03
525 0.00e+00 +-1.08e-02
605 1.76e-02 +-6.45e-03
725 0.00e+00 +-5.31e-03
885 2.93e-03 +-2.62e-03
1085 7.04e-03 +-2.93e-03
1285 7.04e-03 +-4.00e-03
1485 4.69e-03 +-3.77e-03
1685 2.35e-03 +-1.83e-03
1885 0.00e+00 +-9.15e-04
\END;
/*===================================================================*/
|