/* NRDF D1809 Data No.33 */
/*===================================================================*/
/* Bibliography */
/*===================================================================*/
\\BIB,33;
D#=D1809;
TITLE=/Spectral measurements of neutrons, protons, deuterons and
tritons produced by 100 MeV/nucleon He bombardment/;
PURPOSE=/To present the angular-energy distributions of neutrons,
protons, deuterons and tritons produced from thick carbon,
aluminum, copper and lead targets bombarded by 100 MeV/nucleon
helium ion. /;
ATH=(T.KUROSAWA'1', T.NAKAMURA'1', N.NAKAO'2', T.SHIBATA'3',
Y.UWAMINO'4', A.FUKUMURA'5');
INST-ATH=(2JPNTOH'1', 2JPNKEK'2', 2JPNKEK'3', 2JPNIPC'4', 2JPNIRS'5');
/* '1' Cyclotron and Radioisotope Center */
/* '2' Tanashi Branch */
REF=NIM/A;
VLP=430(1999)400;
RCTS=(12C(ALPHA,P)X, 27AL(ALPHA,P)X, CU(ALPHA,P)X, PB(ALPHA,P)X,
12C(ALPHA,D)X, 27AL(ALPHA,D)X, CU(ALPHA,D)X, PB(ALPHA,D)X,
12C(ALPHA,T)X, 27AL(ALPHA,T)X, CU(ALPHA,T)X, PB(ALPHA,T)X);
PHQS=ENGY-SPEC'6';
/* '6' Double differential thick target yield */
/*===================================================================*/
/* Experimental Conditions */
/*===================================================================*/
\\EXP,33;
/* 2003-09-13 : Compiled */
PHQ=ENGY-SPEC'7';
/* '7' Double differential thick target yield */
ENR=X%;
CHM=ELM;
PHYS-FORM=SLD;
POL-TGT=0%;
ALGN-TGT=0%;
ACC=SYN'8';
/* '8' Heavy Ion Medical Accelerator in Chiba (HIMAC) */
INST-ACC=2JPNIRS;
INC-ENGY-LAB=100MEV/A;
POL-PRJ=0%;
COINC=NO;
ANT-COINC=NO;
DET-SYS=(SCT'9',SCT'10',TOF'11',EDE'12');
/* '9' Plastic scintillator (NE102A) was used as the delta-E
counter, ToF start signal detector, and incident projectile
counter */
/* '10' Liquid scintillator (NE213) was used as the E counter */
/* '11' To measure the energy of outgoing neutrons, protons,
deuterons and tritons */
/* '12' To eliminate charged particles */
ANL=MONTE-MTHD'13';
/* '13' LAHET Monte Carlo Code System, LCS [R.E. Prael, H.
Lichtenstein, LA-UR-89-3014, Los Alamos National Laboratory,
1989.] */
/* Experimental Method:
- Time-of-flight (To measure the energy of outgoing neutrons,
protons, deuterons and tritons)
- Particle identification by 'E/Delta E' measurement (To
eliminate charged particles)
RCT=27AL(ALPHA,D)X;
THK-TGT=10800MG/CM**2;
DET-PARTCL=D;
/*===================================================================*/
/* Descriptive Parameters */
/*===================================================================*/
\\DATA,33;
INC-ENGY-LAB=100MEV/A;
SYS-ERR=(<3%'212',<1%'213',<1%'214');
/* '212' Uncertainty in the number of accepted beam particles
incident on the target is estimated to be less than 3%. */
/* '213' Uncertainty in the solid angle for the thickest carbon
target, which has the maximum uncertainty, is less than 1%.
/* '214' Uncertainty of charged particle detection efficiency is
estimated to be 1%, considering a small fraction of the slant
incidence of a particle onto the detector. */
STATIST-ERR=X%'215';
/* '215' The statistical uncertainties vary from 2-5% in the low
to medium energy (5-50 MeV) region of the spectra and
increase to about 30% at the highest energies. */
EMT=D;
THTL=30DEG;
DELTA-DN/DOMEGA/DE=<4%'216';
/* '216' Total normalization uncertainty */
/*===================================================================*/
/* Data Table */
/*===================================================================*/
\DATA;
ENGY-EMT-LAB-MIN ENGY-EMT-LAB-MAX DN/DOMEGA/DE'217'
(MEV) (MEV) (1/SR/MEV/PARTCL)
39.027 43.199 4.7080e-05
43.199 48.087 8.9708e-05
48.087 53.386 8.7054e-05
53.386 59.066 8.9932e-05
59.066 65.720 7.6355e-05
65.720 72.816 7.1273e-05
72.816 81.154 5.8246e-05
81.154 89.979 5.0391e-05
89.979 100.37 3.8638e-05
100.37 111.24 3.1268e-05
111.24 124.04 1.7309e-05
124.04 137.21 1.5292e-05
137.21 152.69 8.0917e-06
152.69 171.08 3.4066e-06
171.08 189.76 2.7527e-06
189.76 211.87 1.0672e-06
\END;
/*===================================================================*/
|