/* NRDF D1769 Data No.33 */
/*===================================================================*/
/* Bibliography */
/*===================================================================*/
\\BIB,33;
D#=D1769;
TITLE=/ Double-differential cross sections for the neutron
production from heavy-ion reactions at energies E/A = 290-600
MeV /;
PURPOSE=/ Systematic measurements of neutron-production cross
sections from C, Ne, and Ar projectiles having E/A = 290-600
MeV on C, Cu, and Pb targets. /;
ATH=(Y.IWATA'1', T.MURAKAMI'1', H.SATO'2', H.IWASE'2', T.NAKAMURA'2',
T.KUROSAWA'2', L.HEILBRONN'3', R.M.RONNINGEN'4', K.IEKI'5',
Y.TOZAWA'5', K.NIITA'6');
INST-ATH=(2JPNIRS'1', 2JPNTOH'2', 1USABRK'3', 1USAMSU'4', 2JPNRIK'5',
2JPNJPN'6');
/* '1' Department of Accelerator Physics and Engineering */
/* '2' Cyclotron and Radioisotope Center */
/* '4' National Superconducting Cyclotron Laboratory */
/* '5' Department of Physics */
/* '6' Research Organization for Information Science and
Technology, Tokai, Naka, Ibaraki */
REF=PR/C;
VLP=64(2001)054609;
RCTS=(C(12C,N)X, CU(12C,N)X, PB(12C,N)X, C(20NE,N)X, CU(20NE,N)X,
PB(20NE,N)X, C(40AR,N)X, CU(40AR,N)X, PB(40AR,N)X);
PHQS=(ENGY-SPEC, ANGL-DSTRN, XSECTN, TOT-XSECTN, MLT);
/*===================================================================*/
/* Experimental Conditions */
/*===================================================================*/
\\EXP,33;
/* 2002-08-01 : Compiled, Am + Sr + On */
/* 2006-07-25 : Altered, On. Heading of data error corrected.
Systematic uncertainties added. */
RTY=HEAVY-ION-RCT;
ENR=NAT;
CHM=ELM;
PHYS-FORM=SLD;
BAC=X;
POL-TGT=0%;
ALGN-TGT=0%;
ACC=SYN'7';
/* '7' Heavy Ion Medical Accelerator in Chiba (HIMAC) facility
INST-ACC=2JPNIRS;
BEAM-INTNSTY=XMA'8';
/* '8' A few times 10e4-10e5 particles per pulse */
POL-PRJ=0%;
DET-PARTCL=N;
COINC=NO;
ANT-COINC=NO;
DET-SYS=(SCT'9',SCT'10',TOF);
/* '9' NE102A plastic scintillator */
/* '10' NE213 liquid scintillator */
ERS-DET=XKEV'11';
/* '11' The energy resolutions are shown in Table I in reference.
/* Experimental Method:
- Time-of-flight
RCT=CU(12C,N)X;
PHQ=ENGY-SPEC;
THK-TGT=13400MG/CM**2;
INC-ENGY-LAB=400.0MEV/A;
ANL=X'109';
/* '109' Moving-source model, QMD and HIC */
/*===================================================================*/
/* Descriptive Parameters */
/*===================================================================*/
\\DATA,33;
SYS-ERR=10%'12';
/* '12' Uncertainty in detection efficiency */
INC-ENGY-LAB=400.0MEV/A;
SYS-ERR=2.5%'110';
/* '110' Uncertainty in target thickness */
THTL=40DEG;
/*===================================================================*/
/* Data Table */
/*===================================================================*/
\DATA;
ENGY-EMT-LAB DSIGMA/DOMEGA/DE DELTA-DSIGMA/DOMEGA/DE'111'
(MEV) (MB/SR/MEV) (MB/SR/MEV)
5 56.7 +-3.9
6 40.9 +-3.0
7 38.4 +-2.7
8 28.1 +-2.4
9 23.2 +-2.2
10 20.1 +-2.1
15 10.7 +-0.5
25 8.05 +-0.47
35 8.24 +-0.50
45 6.65 +-0.45
55 5.67 +-0.48
65 5.73 +-0.46
75 6.16 +-0.48
85 5.37 +-0.49
95 4.94 +-0.44
105 4.51 +-0.42
125 4.88 +-0.32
145 3.69 +-0.28
165 3.45 +-0.22
185 2.87 +-0.21
205 2.38 +-0.20
235 2.07 +-0.17
265 1.67 +-0.13
295 0.895 +-0.111
325 0.996 +-0.103
365 0.763 +-0.082
405 0.534 +-0.062
465 0.305 +-0.035
525 0.183 +-0.030
605 7.63e-02 +-1.65e-02
725 6.10e-02 +-1.18e-02
885 2.29e-02 +-6.44e-03
1085 3.05e-03 +-2.45e-03
1285 0.00e+00 +-4.63e-03
1485 3.05e-03 +-2.58e-03
1685 6.10e-03 +-2.74e-03
1885 3.05e-03 +-1.77e-03
\END;
/*===================================================================*/
|