/* NRDF D1523 Data No.32 */
/*===================================================================*/
/* Bibliography */
/*===================================================================*/
\\BIB,32;
D#=D1523;
TITLE=/ Hole strengths and spreading widths observed in
92Mo(p,d)91Mo reaction at 65 MeV /;
PURPOSE=/ To assign spin-parities and determine spectroscopic
factors of excited neutron-hole states of 91Mo nuclei in the
excitation energy region of 0-10 MeV /;
ATH=(K.HISAMOCHI'1', O.IWAMOTO'1', A.KISANUKI'1', S.BUDIHARDJO'1',
S.WIDODO'1', A.NOHTOMI'1', Y.UOZUMI'1', T.SAKAE'1', M.MATOBA'1',
M.NAKANO'2', T.MAKI'2', S.MATSUKI'3', N.KOORI'4');
INST-ATH=(2JPNKYU'1', 2JPNKIT'2', 2JPNKTO'3', 2JPNTKS'4');
/* '1' Faculty of Engineering */
/* '2' School of Nursing and Technology */
/* '3' Chemical Research Institute */
/* '4' College of General Education */
REF=NP/A;
VLP=564(1993)227;
RCTS=92MO(P,D)91MO;
PHQS=(ANGL-DSTRN, VCTR-ANALPW, SPEC-FCTR);
/*===================================================================*/
/* Experimental Conditions */
/*===================================================================*/
\\EXP,32;
/* 2005-10-12 : Converted, Kc + Sr + On. Converted to EXFOR E523
/* 2005-11-12 : Altered, On + Kc + Sr. Re-digitized */
ENR=X%'5';
/* '5' Enriched target */
CHM=ELM;
PHYS-FORM=SLD;
THK-TGT=0.506MG/CM**2;
POL-TGT=0%;
ALGN-TGT=0%;
ACC=CYC'6';
/* '6' Isochronous cyclotron, AVF cyclotron */
INST-ACC=2JPNRCN;
INC-ENGY-LAB=65MEV;
POL-PRJ=X%'7';
/* '7' A polarized proton beam was used */
DET-PARTCL=D;
COINC=NO;
ANT-COINC=NO;
DET-SYS=MAG'8';
/* '8' Spectrograph RAIDEN [H. Ikegami et al., Nucl. Instr. Meth.
175(1980)33] viewed with the focal plane detector system KYUSHU
[M. Matoba et al., Nucl. Instr. Meth. 180(1980)419] */
ERS-DET=40KEV;
ANL=DWBA;
RCT=92MO(P,D)91MO;
PHQ=VCTR-ANALPW;
/*===================================================================*/
/* Descriptive Parameters */
/*===================================================================*/
\\DATA,32;
INC-ENGY-LAB=65MEV;
SYS-ERR=X%'120';
/* '120' Uncertainty in run-to-run variations of the integrated
beam current are on the order of a few percent. */
EMT=D;
EXC-ENGY=2.901MEV;
J-PTY=3/2-;
TRNSF-L=1'121';
/* '121' Transferred orbital angular momentum (L) */
TRNSF-J=3/2'122';
/* '122' Transferred total angular momentum (J) */
/*===================================================================*/
/* Data Table */
/*===================================================================*/
\DATA;
THTC AY DELTA-AY
(DEG) (NODIM) (NODIM)
4.583E+00 1.689E-01 +-1.130E-01
7.631E+00 -7.688E-02 +-1.200E-01
1.090E+01 2.255E-01 +-1.294E-01
1.372E+01 3.261E-03 +-1.271E-01
1.690E+01 -8.496E-02 +-1.247E-01
2.012E+01 4.564E-02 +-9.884E-02
2.298E+01 1.458E-01 +-8.707E-02
2.613E+01 1.682E-01 +-8.472E-02
2.936E+01 -1.201E-01 +-1.082E-01
3.227E+01 2.475E-02 +-1.200E-01
3.534E+01 2.919E-01 +-8.707E-02
4.051E+01 3.488E-01 +-1.106E-01
4.564E+01 2.152E-01 +-1.153E-01
\END;
/*===================================================================*/
|