/* NRDF D0682 Data No.31 */
/*===================================================================*/
/* Bibliography */
/*===================================================================*/
\\BIB,31;
D#=D682;
TITLE=/Elastic scattering of 56 MeV polarized deuterons from complex
nuclei/;
ATH=(K.HATANAKA'1', K.IMAI'2', S.KOBAYASHI'2', T.MATSUSUE'2',
M.NAKAMURA'2', K.NISIMURA'2', T.NORO'2', H.SAKAMOTO'2',
H.SHIMIZU'2', J.SHIRAI'2');
INST-ATH=(2JPNRCN'1', 2JPNKTO'2');
/* '2' Department of Physics */
REF=NP/A;
VLP=340(1980)93;
RCTS=(16O(D,D)16O, 24MG(D,D)24MG, 28SI(D,D)28SI, 32S(D,D)32S,
40AR(D,D)40AR, 40CA(D,D)40CA, 44CA(D,D)44CA, 54FE(D,D)54FE,
58NI(D,D)58NI, 60NI(D,D)60NI, 64NI(D,D)64NI, 90ZR(D,D)90ZR,
118SN(D,D)118SN, 208PB(D,D)208PB);
PHQS=(ANGL-DSTRN, ANALPW, SPIN-CORRL-PARA, OPT-POTL-PARA);
/*===================================================================*/
/* Experimental Conditions */
/*===================================================================*/
\\EXP,31;
/* 2004-11-24 : Converted, Converted to EXFOR E682 */
RTY=ELA-SCATT;
BAC=SELF'3';
/* '3' for solid target (foil) */
ACC=CYC'4';
/* '4' Isochronous cyclotron, AVF cyclotron */
INST-ACC=2JPNRCN;
INC-ENGY-LAB=56MEV;
DELTA-INC-ENGY-LAB=XKEV;
ERS-PRJ=XKEV;
BEAM-INTNSTY=5[20NA;
POL-PRJ=[75%'5';
/* '5' 70-80% */
ION-SOURCE=/ Atomic beam source (See Table 1 in p95 of reference for
detail.) /;
DET-PARTCL=D;
COINC=NO;
ANT-COINC=NO;
DET-SYS=(SI'6',HPGE'7',NAI'8',EDE);
/* '6' To detect deuteron, transmission type */
/* '7' To detect deuteron, cooled by liquid nitrogen */
/* '8' To monitor beam current and polarization, NaI (Tl)
scintillator */
ERS-DET=200KEV;
ANL=OPT-MODEL'9';
/* '9' With and without tensor potentials */
/* Experimental Method:
- Particle identification by 'E/Delta E' measurement
RCT=54FE(D,D)54FE;
PHQ=SPIN-CORRL-PARA;
ENR=96.81%;
CHM=ELM;
PHYS-FORM=SLD;
THK-TGT=1.55MG/CM**2;
/*===================================================================*/
/* Descriptive Parameters */
/*===================================================================*/
\\DATA,31;
INC-ENGY-LAB=56MEV;
RSD=54FE;
DELTA-DSIGMA/DOMEGA=10%'113';
/* '113' Uncertainty due to normalization of analyzing power of
carbon polarimeter */
/*===================================================================*/
/* Data Table */
/*===================================================================*/
\DATA;
THTC AYY DELTA-AYY'114'
(DEG) (NODIM) (NODIM)
14.53 0.013 0.021
15.57 -0.075 0.037
16.61 -0.055 0.033
18.68 0.010 0.022
20.75 0.053 0.014
22.82 0.100 0.023
24.90 0.051 0.042
26.96 -0.132 0.108
28.00 -0.395 0.085
29.03 -0.265 0.084
31.10 -0.107 0.047
33.68 0.159 0.045
36.26 0.376 0.036
38.84 0.403 0.078
40.38 0.053 0.053
41.41 -0.123 0.047
43.99 -0.095 0.035
49.12 0.044 0.040
51.69 0.057 0.048
54.25 0.045 0.054
56.80 -0.033 0.058
59.36 -0.297 0.055
61.91 -0.098 0.060
64.45 -0.131 0.066
66.99 -0.183 0.079
69.53 -0.067 0.090
72.07 0.090 0.074
74.60 -0.005 0.098
\END;
/*===================================================================*/
|