/* NRDF D1996 Data No.3 */
/*===================================================================*/
/* Bibliography */
/*===================================================================*/
\\BIB,3;
D#=D1996;
TITLE=/ Alpha beam monitoring via natCu + alpha processes in the
energy range from 40 to 60 MeV /;
ATH=(F.SZELECSENYI'1', K.SUZUKI'2', Z.KOVACS'1', M.TAKEI'2',
K.OKADA'2');
INST-ATH=(3HUNDEB'1', 2JPNIRS'2');
/* '1' Cyclotron Department */
/* '2' Division of Advanced Technology for Medical Imaging */
REF=NIM/B;
VLP=184(2001)589;
RCTS=(CU(ALPHA,X)61CU, CU(ALPHA,X)66GA, CU(ALPHA,X)67GA);
PHQS=XSECTN;
/*===================================================================*/
/* Experimental Conditions */
/*===================================================================*/
\\EXP,3;
/* 2006-09-06 : Compiled, Tk + On */
PHQ=XSECTN;
CHM=ELM;
PHYS-FORM=SLD;
POL-TGT=0%;
ALGN-TGT=0%;
ACC=CYC'3';
/* '3' Isochronous cyclotron, AVF cyclotron */
INST-ACC=2JPNIRS;
BEAM-INTNSTY=(94NA,96NA,183NA);
POL-PRJ=0%;
COINC=NO;
ANT-COINC=NO;
DET-SYS=HPGE'4';
/* '4' To determine activity of samples */
/* Experimental Method:
- Activation (Irradiated for 10, 20 and 30 min (3 runs))
- Stacked target irradiation (Stacks made up of natCu and natCo)
- Beam current integrated (Via electric charge collection in
Faraday cage)
/* Related references
- common, A0465006, J(Pram)31.
. See also EXFOR commo.n.
- Compared with present result, A0510375, B(Levk).
. See also EXFOR 109..
- Compared with present result, A0353003, J(Radi)39.
- Compared with present result, D4085003, J(Nucl)168.
. See also EXFOR 61..
RCT=CU(ALPHA,X)67GA;
INC-ENGY-LAB=15[59MEV;
DET-PARTCL=GAMMA'18';
/* '18' Delayed gamma from 67Ga */
/*===================================================================*/
/* Descriptive Parameters */
/*===================================================================*/
\\DATA,3;
TOT-ERR=12%;
SYS-ERR=(8%'5',5%'6',3%'7');
/* '5' Uncertainty in flux measurement */
/* '6' Uncertainty in detector efficiency */
/* '7' Uncertainty in nuclear data */
STATIST-ERR=<1%'8';
/* '8' Maximum uncertainty in counting statistics */
ENGY-GAMMA=(93.31KEV'19',184.57KEV'20',300.21KEV'21');
INTNSTY-GAMMA=(0.370'19',0.204'20',0.166'21');
HALF-LIFE=(3.261DAY'21',3.261DAY'20',3.261DAY'19');
/* '19' Delayed gamma from 67Ga via NONe */
/* '20' Delayed gamma from 67Ga via NONe */
/* '21' Delayed gamma from 67Ga via NONe */
/*===================================================================*/
/* Data Table */
/*===================================================================*/
\DATA;
INC-ENGY-LAB DELTA-INC-ENGY-LAB'22' SIGMA DELTA-SIGMA
(MEV) (MEV) (MB) (MB)
15.9 +-1.9 8.12 +-0.89
19.2 +-1.7 97.8 +-10.8
20.8 +-2.6 237.2 +-26.1
22.3 +-1.6 238.7 +-26.3
25.1 +-1.5 338.4 +-37.2
25.7 +-2.3 344.6 +-37.9
27.7 +-1.3 351.2 +-38.6
28.9 +-2.2 348.9 +-38.0
30.0 +-1.2 340.7 +-37.0
32.1 +-2.0 275.8 +-30.3
32.3 +-1.1 296.8 +-32.3
34.2 +-1.9 197.2 +-21.6
34.4 +-1.0 240.6 +-26.2
35.3 +-1.8 185.0 +-20.1
36.5 +-0.9 190.3 +-21.0
37.9 +-1.7 119.1 +-13.1
38.3 +-1.7 126.9 +-14.0
40.3 +-0.7 99.5 +-11.0
41.1 +-1.5 76.8 +-8.5
41.2 +-1.5 57.8 +-6.4
43.7 +-1.4 54.3 +-6.0
44.5 +-1.4 40.8 +-4.1
46.8 +-1.3 40.9 +-4.5
47.6 +-1.2 38.6 +-4.3
49.9 +-1.1 32.3 +-3.5
50.6 +-1.1 34.4 +-3.8
52.7 +-1.0 30.9 +-3.4
53.3 +-0.9 23.0 +-2.6
55.4 +-0.8 26.3 +-2.9
56.0 +-0.8 20.7 +-2.3
58.1 +-0.7 26.7 +-2.9
\END;
/*===================================================================*/
|