/* NRDF D1988 Data No.3 */
/*===================================================================*/
/* Bibliography */
/*===================================================================*/
\\BIB,3;
D#=D1988;
TITLE=/ Measurements of deuteron-induced activation cross-sections
for IFMIF accelerator structural materials /;
ATH=(M.NAKAO'1', J.HORI'1', K.OCHIAI'1', N.KUBOTA'1', S.SATO'1',
M.YAMAUCHI'1', N.S.ISHIOKA'2', T.NISHITANI'1');
INST-ATH=(2JPNJAE'1', 2JPNJAE'2');
/* '1' Department of Fusion Engineering Research */
/* '2' Department of Radiation Research for Environment and
Resources */
REF=NIM/A;
VLP=562(2006)785;
/* '3' Proceedings of the 7th International Conference on
Accelerator Applications (AccApp05) */
/* Secondary reference
- Kubota, Private communication(2006)
RCTS=(27AL(D,X)22NA, 27AL(D,X)24NA, FE(D,X)55CO, FE(D,X)56CO,
CU(D,X)61CU, CU(D,X)62ZN, TA(D,X)178TA, TA(D,X)180TA,
W(D,X)181RE, W(D,X)183RE);
PHQS=XSECTN;
/*===================================================================*/
/* Experimental Conditions */
/*===================================================================*/
\\EXP,3;
/* 2006-06-13 : Compiled+Checked, C.Kurokawa + N.Otuka */
/* 2006-07-11 : Received, N.Otuka. Received by e-mail from
N.Kubota */
/* 2009-03-18 : Altered, N.Otuka. 003, 005, 009 corrected */
/* Related references
- S.Takacs et al., NIM/B, 174(2001)235.
Reference for monitor (Referred to determine number of incident
deuterons on each foil). See also EXFOR D4081.
PHQ=XSECTN;
CHM=ELM'4';
/* '4' Chemical purity of more than 99.95% */
PHYS-FORM=SLD;
POL-TGT=0%;
ALGN-TGT=0%;
ACC=CYC'5';
/* '5' Isochronous cyclotron, AVF cyclotron */
INST-ACC=2JPNJAE'6';
/* '6' TIARA facility (at Takasaki) */
POL-PRJ=0%;
COINC=NO;
ANT-COINC=NO;
DET-SYS=HPGE'7';
/* '7' To measure decay gamma-rays */
ANL=X'8';
/* '8' ACSELAM library calculated from ALICE-F code (Evaporation +
Pre-equilibrium) */
/* Experimental Method:
- Activation (Irradiated for a few minutes)
- Stacked target irradiation
/* Related references
- J.W.Clark et al., PR, 179(1969)1104.
Reference with which data agree (In agreement within 60%). See also
EXFOR T0199.007.
- A.Hermanne et al., NIM/B, 161-163(2000)178.
Reference with which data agree (In agreement within 30%). See also
EXFOR D4082.003.
RCT=FE(D,X)55CO;
THK-TGT=XMG/CM**2'19';
/* '19' 50 micro-meter */
DET-PARTCL=GAMMA'20';
/* '20' Delayed gamma from 55Co */
MONTR-RCT=/ CU(D,X)65ZN /;
/*===================================================================*/
/* Descriptive Parameters */
/*===================================================================*/
\\DATA,3;
HALF-LIFE=17.5HOUR'21';
/* '21' Delayed gamma from 55Co */
/*===================================================================*/
/* Data Table */
/*===================================================================*/
\DATA;
INC-ENGY-LAB SIGMA DELTA-SIGMA'22'
(MEV) (MB) (MB)
16.2 4.1 +-0.5
18.1 3.7 +-0.5
20.4 4.1 +-0.6
20.6 4.3 +-0.6
22.2 9.0 +-1.2
23.2 12.8 +-1.7
23.6 14.5 +-1.9
26.0 18.2 +-2.4
26.4 18.1 +-2.4
27.7 24.5 +-3.3
28.5 26.7 +-3.6
29.5 31.4 +-4.2
30.6 31.6 +-4.4
31.3 34.8 +-4.8
32.4 37.7 +-5.4
33.4 40.3 +-4.4
33.6 37.6 +-5.9
35.0 38.7 +-5.8
36.6 37.6 +-5.7
38.1 32.3 +-4.9
39.6 30.6 +-4.6
\END;
/*===================================================================*/
|