/* NRDF D1927 Data No.3 */
/*===================================================================*/
/* Bibliography */
/*===================================================================*/
\\BIB,3;
D#=D1927;
TITLE=/ Experimental studies on excitation functions of the
proton-induced activation reactions on silver /;
PURPOSE=/ To present the cross-section measurement for Ag-p reaction
in the enegy range 11-80 MeV. /;
ATH=(M.S.UDDIN'1', M.HAGIWARA'1', M.BABA'1', F.TARKANYI'2',
F.DITROI'2');
INST-ATH=(2JPNTOH'1', 3HUNDEB'2');
/* '1' Cyclotron and Radioisotope Center */
REF=ARI;
VLP=62(2005)533;
/* Secondary reference
- UDDIN, Private communication(2005)
RCTS=(AG(P,X)103PD, AG(P,X)101PD, AG(P,X)100PD, AG(P,X)99RH,
AG(P,X)100RH, AG(P,X)101RH, AG(P,X)102RH, AG(P,X)105RH,
AG(P,X)97RU, AG(P,X)105AG, AG(P,X)106AG);
PHQS=XSECTN;
/*===================================================================*/
/* Experimental Conditions */
/*===================================================================*/
\\EXP,3;
/* 2005-06-29 : Compiled, Tk + On. */
PHQ=XSECTN;
ENR=NAT;
CHM=ELM;
PHYS-FORM=SLD;
THK-TGT=XMG/CM**2'3';
/* '3' 50 and 300 micrometer thick */
POL-TGT=0%;
ALGN-TGT=0%;
ACC=CYC'4';
/* '4' Isochronous cyclotron, AVF cyclotron */
INST-ACC=2JPNTOH'5';
/* '5' Cyclotron and Radioisotope Center */
POL-PRJ=0%;
COINC=NO;
ANT-COINC=NO;
DET-SYS=HPGE'6';
/* '6' To measure activities in silver target and monitors */
/* Experimental Method:
- Activation ( Irradiated separately with 50, 70 and 80 MeV
proton beam)
- Stacked target irradiation (Three stacks containing high-purity
thin silver foils)
- Gamma ray spectrometry (Measurement started 1 day after the end
of bombardment)
/* Related references
- M.Fassbender et al., RCA, 87(1999)87.
Reference with which data disagree (Systematically lower than the
present data in higher energy)
- Y.N.Shubin et al., IAEA-NDS-, 204(1998).
Reference with which data agree (Shape similar to the present data)
RCT=AG(P,X)100PD;
DET-PARTCL=GAMMA'19';
/* '19' Delayed gamma from 100Pd */
/*===================================================================*/
/* Descriptive Parameters */
/*===================================================================*/
\\DATA,3;
TOT-ERR=X%'7';
/* '7' Uncertainty estimated from the uncertaintiies of the flux,
counting area and detector efficiency */
SYS-ERR=(5%'8',3%'9');
/* '8' Upper limit of uncertainty in monitor flux (2.54-5%) */
/* '9' Upper limit of uncertainty in efficiency calibration of
gamma-ray (1-3%) */
STATIST-ERR=22%'10';
/* '10' Upper limit of statistical uncertainty (0.8-22%) */
ENGY-GAMMA=84KEV'20';
INTNSTY-GAMMA=0.45'20';
HALF-LIFE=3.63DAY'20';
/* '20' Delayed gamma from 100Pd */
/*===================================================================*/
/* Data Table */
/*===================================================================*/
\DATA;
INC-ENGY-LAB XSECTN'21' DELTA-XSECTN'21'
(MEV) (MB) (MB)
30.26 1.48 +-0.10
33.29 1.39 +-0.10
38.57 1.44 +-0.11
42.70 1.77 +-0.13
47.26 2.46 +-0.15
50.91 4.76 +-0.23
55.03 11.57 +-0.48
58.23 17.76 +-0.72
61.89 23.81 +-0.99
63.35 24.97 +-1.44
64.98 25.79 +-1.05
68.61 24.39 +-1.45
73.40 20.87 +-1.24
78.12 19.89 +-1.18
\END;
/*===================================================================*/
|