/* NRDF D0815 Data No.3 */
/*===================================================================*/
/* Bibliography */
/*===================================================================*/
\\BIB,3;
D#=D815;
TITLE=/Analyzing power of the neutron continuum spectrum for the
93Nb(p,nX) reaction at 65 MeV and a DWBA analysis/;
PURPOSE=/To provide stringent test for various theories by simultaneous
fitting of analyzing powers as well as cross sections for both
neutron and proton spectra/;
ATH=(H.SAKAI'1', K.HATANAKA'1', N.MATSUOKA'1', T.SAITO'1',
A.SHIMIZU'1', T.MOTOBAYASHI'2', T.SHIBATA'1');
INST-ATH=(2JPNRCN'1', 2JPNOSA'2');
/* '2' Department of Physics */
REF=PL/B;
VLP=133(1983)375;
RCTS=93NB(P,N)X;
PHQS=(ENGY-SPEC'3', ANALPW, ANGL-DSTRN);
/* '3' Double differential cross section */
/*===================================================================*/
/* Experimental Conditions */
/*===================================================================*/
\\EXP,3;
/* 2003-10-24 : Converted, Data converted to EXFOR E815 and EXFOR
O0522 */
ENR=X%;
CHM=ELM;
PHYS-FORM=SLD'4';
/* '4' Metallic foil */
THK-TGT=43.6MG/CM**2;
BAC=SELF;
POL-TGT=0%;
ALGN-TGT=0%;
ACC=CYC'5';
/* '5'Isochronous cyclotron, RCNP AVF cyclotron */
INST-ACC=2JPNRCN;
INC-ENGY-LAB=65MEV;
BEAM-INTNSTY=50NA'6';
/* '6' maximum beam current */
POL-PRJ=82.5+-2.5%'7';
/* '7' The beam polarization was measured continuously with a
12C-polarimeter placed down stream the main scattering chamber
DET-PARTCL=N;
COINC=NO;
ANT-COINC=NO;
DET-SYS=SCT'8';
/* '8' two liquid scintillation counters (NE213) to detect
neutrons */
/* Experimental Method:
- Time-of-flight (To determine outgoing neutron energy. The time
resolution (FWHM) of the beam burst was typically 1.0-1.5 ns, and
corresponding energy resolutions of the neutrons were about 4 and
2 MeV for 50 and 30 MeV neutrons, respectively.)
RCT=93NB(P,N)X;
PHQ=ENGY-SPEC'17';
/* '17' Double differential cross section */
/*===================================================================*/
/* Descriptive Parameters */
/*===================================================================*/
\\DATA,3;
INC-ENGY-LAB=65MEV;
SYS-ERR=10%'18';
/* '18' Estimated errors in the absolute magnitude of the cross
section due to uncertainties in the neutron detection
efficiency calculation */
EMT=N;
THTL=70DEG;
DELTA-ENGY-EMT-LAB=0.27MEV'19';
/* '19' Data-point reader uncertainty */
DELTA-DSIGMA/DOMEGA/DE=+-3.0%'20';
/* '20' Data-point reader uncertainty */
/*===================================================================*/
/* Data Table */
/*===================================================================*/
\DATA;
ENGY-EMT-LAB DSIGMA/DOMEGA/DE
(MEV) (MB/SR/MEV)
16.43 1.07
17.24 0.944
19.19 0.891
20.39 0.788
21.39 0.711
22.57 0.67
23.56 0.605
24.93 0.583
26.49 0.561
27.66 0.551
29.23 0.52
30.22 0.479
31.98 0.462
34.14 0.41
35.33 0.378
36.9 0.357
38.27 0.336
40.44 0.292
42.03 0.248
43.03 0.224
44.21 0.215
45. 0.198
46.01 0.172
47.38 0.165
47.99 0.149
48.79 0.135
49.98 0.124
50.79 0.107
52.18 0.095
52.99 0.0822
53.79 0.0757
54.8 0.0642
56.24 0.047
56.91 0.0344
58.16 0.0241
59.04 0.0162
59.59 0.00882
60.93 0.00451
\END;
/*===================================================================*/
|