/* NRDF D1809 Data No.29 */
/*===================================================================*/
/* Bibliography */
/*===================================================================*/
\\BIB,29;
D#=D1809;
TITLE=/Spectral measurements of neutrons, protons, deuterons and
tritons produced by 100 MeV/nucleon He bombardment/;
PURPOSE=/To present the angular-energy distributions of neutrons,
protons, deuterons and tritons produced from thick carbon,
aluminum, copper and lead targets bombarded by 100 MeV/nucleon
helium ion. /;
ATH=(T.KUROSAWA'1', T.NAKAMURA'1', N.NAKAO'2', T.SHIBATA'3',
Y.UWAMINO'4', A.FUKUMURA'5');
INST-ATH=(2JPNTOH'1', 2JPNKEK'2', 2JPNKEK'3', 2JPNIPC'4', 2JPNIRS'5');
/* '1' Cyclotron and Radioisotope Center */
/* '2' Tanashi Branch */
REF=NIM/A;
VLP=430(1999)400;
RCTS=(12C(ALPHA,P)X, 27AL(ALPHA,P)X, CU(ALPHA,P)X, PB(ALPHA,P)X,
12C(ALPHA,D)X, 27AL(ALPHA,D)X, CU(ALPHA,D)X, PB(ALPHA,D)X,
12C(ALPHA,T)X, 27AL(ALPHA,T)X, CU(ALPHA,T)X, PB(ALPHA,T)X);
PHQS=ENGY-SPEC'6';
/* '6' Double differential thick target yield */
/*===================================================================*/
/* Experimental Conditions */
/*===================================================================*/
\\EXP,29;
/* 2003-09-13 : Compiled */
PHQ=ENGY-SPEC'7';
/* '7' Double differential thick target yield */
ENR=X%;
CHM=ELM;
PHYS-FORM=SLD;
POL-TGT=0%;
ALGN-TGT=0%;
ACC=SYN'8';
/* '8' Heavy Ion Medical Accelerator in Chiba (HIMAC) */
INST-ACC=2JPNIRS;
INC-ENGY-LAB=100MEV/A;
POL-PRJ=0%;
COINC=NO;
ANT-COINC=NO;
DET-SYS=(SCT'9',SCT'10',TOF'11',EDE'12');
/* '9' Plastic scintillator (NE102A) was used as the delta-E
counter, ToF start signal detector, and incident projectile
counter */
/* '10' Liquid scintillator (NE213) was used as the E counter */
/* '11' To measure the energy of outgoing neutrons, protons,
deuterons and tritons */
/* '12' To eliminate charged particles */
ANL=MONTE-MTHD'13';
/* '13' LAHET Monte Carlo Code System, LCS [R.E. Prael, H.
Lichtenstein, LA-UR-89-3014, Los Alamos National Laboratory,
1989.] */
/* Experimental Method:
- Time-of-flight (To measure the energy of outgoing neutrons,
protons, deuterons and tritons)
- Particle identification by 'E/Delta E' measurement (To
eliminate charged particles)
RCT=12C(ALPHA,D)X;
THK-TGT=8850MG/CM**2;
DET-PARTCL=D;
/*===================================================================*/
/* Descriptive Parameters */
/*===================================================================*/
\\DATA,29;
INC-ENGY-LAB=100MEV/A;
SYS-ERR=(<3%'187',<1%'188',<1%'189');
/* '187' Uncertainty in the number of accepted beam particles
incident on the target is estimated to be less than 3%. */
/* '188' Uncertainty in the solid angle for the thickest carbon
target, which has the maximum uncertainty, is less than 1%.
/* '189' Uncertainty of charged particle detection efficiency is
estimated to be 1%, considering a small fraction of the slant
incidence of a particle onto the detector. */
STATIST-ERR=X%'190';
/* '190' The statistical uncertainties vary from 2-5% in the low
to medium energy (5-50 MeV) region of the spectra and
increase to about 30% at the highest energies. */
EMT=D;
THTL=60DEG;
DELTA-DN/DOMEGA/DE=<4%'191';
/* '191' Total normalization uncertainty */
/*===================================================================*/
/* Data Table */
/*===================================================================*/
\DATA;
ENGY-EMT-LAB-MIN'192' ENGY-EMT-LAB-MAX DN/DOMEGA/DE'193'
(MEV) (MEV) (1/SR/MEV/PARTCL)
X 38.879 1.1847e-06
38.879 43.199 1.1175e-06
43.199 48.291 5.1711e-07
48.291 53.626 7.4048e-07
53.626 59.911 5.5862e-07
59.911 66.381 3.7310e-07
66.381 73.981 3.7537e-07
73.981 82.997 2.4339e-07
82.997 92.140 9.6010e-08
92.140 102.93 2.0345e-08
\END;
/*===================================================================*/
|