|
| /*===================================================================*/
/* NRDF D1809 Data No.28 */
/*===================================================================*/
/* Bibliography */
/*===================================================================*/
\\BIB,28;
D#=D1809;
TITLE=/Spectral measurements of neutrons, protons, deuterons and
tritons produced by 100 MeV/nucleon He bombardment/;
PURPOSE=/To present the angular-energy distributions of neutrons,
protons, deuterons and tritons produced from thick carbon,
aluminum, copper and lead targets bombarded by 100 MeV/nucleon
helium ion. /;
ATH=(T.KUROSAWA'1', T.NAKAMURA'1', N.NAKAO'2', T.SHIBATA'3',
Y.UWAMINO'4', A.FUKUMURA'5');
INST-ATH=(2JPNTOH'1', 2JPNKEK'2', 2JPNKEK'3', 2JPNIPC'4', 2JPNIRS'5');
/* '1' Cyclotron and Radioisotope Center */
/* '2' Tanashi Branch */
REF=NIM/A;
VLP=430(1999)400;
RCTS=(12C(ALPHA,P)X, 27AL(ALPHA,P)X, CU(ALPHA,P)X, PB(ALPHA,P)X,
12C(ALPHA,D)X, 27AL(ALPHA,D)X, CU(ALPHA,D)X, PB(ALPHA,D)X,
12C(ALPHA,T)X, 27AL(ALPHA,T)X, CU(ALPHA,T)X, PB(ALPHA,T)X);
PHQS=ENGY-SPEC'6';
/* '6' Double differential thick target yield */
/*===================================================================*/
/* Experimental Conditions */
/*===================================================================*/
\\EXP,28;
/* 2003-09-13 : Compiled */
PHQ=ENGY-SPEC'7';
/* '7' Double differential thick target yield */
ENR=X%;
CHM=ELM;
PHYS-FORM=SLD;
POL-TGT=0%;
ALGN-TGT=0%;
ACC=SYN'8';
/* '8' Heavy Ion Medical Accelerator in Chiba (HIMAC) */
INST-ACC=2JPNIRS;
INC-ENGY-LAB=100MEV/A;
POL-PRJ=0%;
COINC=NO;
ANT-COINC=NO;
DET-SYS=(SCT'9',SCT'10',TOF'11',EDE'12');
/* '9' Plastic scintillator (NE102A) was used as the delta-E
counter, ToF start signal detector, and incident projectile
counter */
/* '10' Liquid scintillator (NE213) was used as the E counter */
/* '11' To measure the energy of outgoing neutrons, protons,
deuterons and tritons */
/* '12' To eliminate charged particles */
ANL=MONTE-MTHD'13';
/* '13' LAHET Monte Carlo Code System, LCS [R.E. Prael, H.
Lichtenstein, LA-UR-89-3014, Los Alamos National Laboratory,
1989.] */
/* Experimental Method:
- Time-of-flight (To measure the energy of outgoing neutrons,
protons, deuterons and tritons)
- Particle identification by 'E/Delta E' measurement (To
eliminate charged particles)
RCT=12C(ALPHA,D)X;
THK-TGT=8850MG/CM**2;
DET-PARTCL=D;
/*===================================================================*/
/* Descriptive Parameters */
/*===================================================================*/
\\DATA,28;
INC-ENGY-LAB=100MEV/A;
SYS-ERR=(<3%'181',<1%'182',<1%'183');
/* '181' Uncertainty in the number of accepted beam particles
incident on the target is estimated to be less than 3%. */
/* '182' Uncertainty in the solid angle for the thickest carbon
target, which has the maximum uncertainty, is less than 1%.
/* '183' Uncertainty of charged particle detection efficiency is
estimated to be 1%, considering a small fraction of the slant
incidence of a particle onto the detector. */
STATIST-ERR=X%'184';
/* '184' The statistical uncertainties vary from 2-5% in the low
to medium energy (5-50 MeV) region of the spectra and
increase to about 30% at the highest energies. */
EMT=D;
THTL=30DEG;
DELTA-DN/DOMEGA/DE=<4%'185';
/* '185' Total normalization uncertainty */
/*===================================================================*/
/* Data Table */
/*===================================================================*/
\DATA;
ENGY-EMT-LAB-MIN ENGY-EMT-LAB-MAX DN/DOMEGA/DE'186'
(MEV) (MEV) (1/SR/MEV/PARTCL)
39.027 43.199 2.6892e-05
43.199 48.087 4.5007e-05
48.087 53.386 4.6324e-05
53.386 59.066 4.6324e-05
59.066 65.720 3.8435e-05
65.720 72.816 3.4315e-05
72.816 81.154 2.8852e-05
81.154 89.979 2.3209e-05
89.979 100.37 1.7074e-05
100.37 111.24 1.3477e-05
111.24 124.04 8.8804e-06
124.04 137.21 7.1034e-06
137.21 152.69 4.9683e-06
152.69 171.08 2.3981e-06
171.08 189.76 1.2588e-06
189.76 211.87 8.6453e-07
\END;
/*===================================================================*/
|