/* NRDF D1769 Data No.28 */
/*===================================================================*/
/* Bibliography */
/*===================================================================*/
\\BIB,28;
D#=D1769;
TITLE=/ Double-differential cross sections for the neutron
production from heavy-ion reactions at energies E/A = 290-600
MeV /;
PURPOSE=/ Systematic measurements of neutron-production cross
sections from C, Ne, and Ar projectiles having E/A = 290-600
MeV on C, Cu, and Pb targets. /;
ATH=(Y.IWATA'1', T.MURAKAMI'1', H.SATO'2', H.IWASE'2', T.NAKAMURA'2',
T.KUROSAWA'2', L.HEILBRONN'3', R.M.RONNINGEN'4', K.IEKI'5',
Y.TOZAWA'5', K.NIITA'6');
INST-ATH=(2JPNIRS'1', 2JPNTOH'2', 1USABRK'3', 1USAMSU'4', 2JPNRIK'5',
2JPNJPN'6');
/* '1' Department of Accelerator Physics and Engineering */
/* '2' Cyclotron and Radioisotope Center */
/* '4' National Superconducting Cyclotron Laboratory */
/* '5' Department of Physics */
/* '6' Research Organization for Information Science and
Technology, Tokai, Naka, Ibaraki */
REF=PR/C;
VLP=64(2001)054609;
RCTS=(C(12C,N)X, CU(12C,N)X, PB(12C,N)X, C(20NE,N)X, CU(20NE,N)X,
PB(20NE,N)X, C(40AR,N)X, CU(40AR,N)X, PB(40AR,N)X);
PHQS=(ENGY-SPEC, ANGL-DSTRN, XSECTN, TOT-XSECTN, MLT);
/*===================================================================*/
/* Experimental Conditions */
/*===================================================================*/
\\EXP,28;
/* 2002-08-01 : Compiled, Am + Sr + On */
/* 2006-07-25 : Altered, On. Heading of data error corrected.
Systematic uncertainties added. */
RTY=HEAVY-ION-RCT;
ENR=NAT;
CHM=ELM;
PHYS-FORM=SLD;
BAC=X;
POL-TGT=0%;
ALGN-TGT=0%;
ACC=SYN'7';
/* '7' Heavy Ion Medical Accelerator in Chiba (HIMAC) facility
INST-ACC=2JPNIRS;
BEAM-INTNSTY=XMA'8';
/* '8' A few times 10e4-10e5 particles per pulse */
POL-PRJ=0%;
DET-PARTCL=N;
COINC=NO;
ANT-COINC=NO;
DET-SYS=(SCT'9',SCT'10',TOF);
/* '9' NE102A plastic scintillator */
/* '10' NE213 liquid scintillator */
ERS-DET=XKEV'11';
/* '11' The energy resolutions are shown in Table I in reference.
/* Experimental Method:
- Time-of-flight
RCT=C(12C,N)X;
PHQ=ENGY-SPEC;
THK-TGT=9000MG/CM**2;
INC-ENGY-LAB=400.0MEV/A;
ANL=X'94';
/* '94' Moving-source model, QMD and HIC */
/*===================================================================*/
/* Descriptive Parameters */
/*===================================================================*/
\\DATA,28;
SYS-ERR=10%'12';
/* '12' Uncertainty in detection efficiency */
INC-ENGY-LAB=400.0MEV/A;
SYS-ERR=6.8%'95';
/* '95' Uncertainty in target thickness */
THTL=80DEG;
/*===================================================================*/
/* Data Table */
/*===================================================================*/
\DATA;
ENGY-EMT-LAB DSIGMA/DOMEGA/DE DELTA-DSIGMA/DOMEGA/DE'96'
(MEV) (MB/SR/MEV) (MB/SR/MEV)
5 4.43 +-0.41
6 2.46 +-0.30
7 2.56 +-0.27
8 1.48 +-0.27
9 1.87 +-0.23
10 1.57 +-0.19
15 0.955 +-0.061
25 0.817 +-0.053
35 0.718 +-0.050
45 0.709 +-0.050
55 0.541 +-0.048
65 0.522 +-0.044
75 0.374 +-0.044
85 0.305 +-0.039
95 0.256 +-0.038
105 0.207 +-0.028
125 0.231 +-0.023
145 0.123 +-0.018
165 6.89e-02 +-1.41e-02
185 7.38e-02 +-1.14e-02
205 4.92e-02 +-1.29e-02
235 2.62e-02 +-7.19e-03
265 1.31e-02 +-4.08e-03
295 6.56e-03 +-5.27e-03
325 9.84e-03 +-3.34e-03
365 4.92e-03 +-4.12e-03
405 2.46e-03 +-1.79e-03
465 3.28e-03 +-2.09e-03
525 1.64e-03 +-2.17e-03
605 1.23e-03 +-7.28e-04
725 1.64e-03 +-7.56e-04
885 6.15e-04 +-4.43e-04
1085 0.00e+00 +-2.33e-04
1285 4.92e-04 +-3.79e-04
1485 4.92e-04 +-3.62e-04
1685 4.92e-04 +-3.55e-04
1885 0.00e+00 +-7.53e-05
\END;
/*===================================================================*/
|