/* NRDF D1769 Data No.26 */
/*===================================================================*/
/* Bibliography */
/*===================================================================*/
\\BIB,26;
D#=D1769;
TITLE=/ Double-differential cross sections for the neutron
production from heavy-ion reactions at energies E/A = 290-600
MeV /;
PURPOSE=/ Systematic measurements of neutron-production cross
sections from C, Ne, and Ar projectiles having E/A = 290-600
MeV on C, Cu, and Pb targets. /;
ATH=(Y.IWATA'1', T.MURAKAMI'1', H.SATO'2', H.IWASE'2', T.NAKAMURA'2',
T.KUROSAWA'2', L.HEILBRONN'3', R.M.RONNINGEN'4', K.IEKI'5',
Y.TOZAWA'5', K.NIITA'6');
INST-ATH=(2JPNIRS'1', 2JPNTOH'2', 1USABRK'3', 1USAMSU'4', 2JPNRIK'5',
2JPNJPN'6');
/* '1' Department of Accelerator Physics and Engineering */
/* '2' Cyclotron and Radioisotope Center */
/* '4' National Superconducting Cyclotron Laboratory */
/* '5' Department of Physics */
/* '6' Research Organization for Information Science and
Technology, Tokai, Naka, Ibaraki */
REF=PR/C;
VLP=64(2001)054609;
RCTS=(C(12C,N)X, CU(12C,N)X, PB(12C,N)X, C(20NE,N)X, CU(20NE,N)X,
PB(20NE,N)X, C(40AR,N)X, CU(40AR,N)X, PB(40AR,N)X);
PHQS=(ENGY-SPEC, ANGL-DSTRN, XSECTN, TOT-XSECTN, MLT);
/*===================================================================*/
/* Experimental Conditions */
/*===================================================================*/
\\EXP,26;
/* 2002-08-01 : Compiled, Am + Sr + On */
/* 2006-07-25 : Altered, On. Heading of data error corrected.
Systematic uncertainties added. */
RTY=HEAVY-ION-RCT;
ENR=NAT;
CHM=ELM;
PHYS-FORM=SLD;
BAC=X;
POL-TGT=0%;
ALGN-TGT=0%;
ACC=SYN'7';
/* '7' Heavy Ion Medical Accelerator in Chiba (HIMAC) facility
INST-ACC=2JPNIRS;
BEAM-INTNSTY=XMA'8';
/* '8' A few times 10e4-10e5 particles per pulse */
POL-PRJ=0%;
DET-PARTCL=N;
COINC=NO;
ANT-COINC=NO;
DET-SYS=(SCT'9',SCT'10',TOF);
/* '9' NE102A plastic scintillator */
/* '10' NE213 liquid scintillator */
ERS-DET=XKEV'11';
/* '11' The energy resolutions are shown in Table I in reference.
/* Experimental Method:
- Time-of-flight
RCT=C(12C,N)X;
PHQ=ENGY-SPEC;
THK-TGT=9000MG/CM**2;
INC-ENGY-LAB=400.0MEV/A;
ANL=X'88';
/* '88' Moving-source model, QMD and HIC */
/*===================================================================*/
/* Descriptive Parameters */
/*===================================================================*/
\\DATA,26;
SYS-ERR=10%'12';
/* '12' Uncertainty in detection efficiency */
INC-ENGY-LAB=400.0MEV/A;
SYS-ERR=6.8%'89';
/* '89' Uncertainty in target thickness */
THTL=40DEG;
/*===================================================================*/
/* Data Table */
/*===================================================================*/
\DATA;
ENGY-EMT-LAB DSIGMA/DOMEGA/DE DELTA-DSIGMA/DOMEGA/DE'90'
(MEV) (MB/SR/MEV) (MB/SR/MEV)
5 5.54 +-0.85
6 3.81 +-0.68
7 3.29 +-0.65
8 2.77 +-0.63
9 2.42 +-0.54
10 2.60 +-0.48
15 1.75 +-0.13
25 1.42 +-0.12
35 1.42 +-0.12
45 1.61 +-0.12
55 1.44 +-0.12
65 1.26 +-0.12
75 1.25 +-0.12
85 1.18 +-0.13
95 1.39 +-0.12
105 1.23 +-0.11
125 1.38 +-0.09
145 1.10 +-0.07
165 0.944 +-0.067
185 0.944 +-0.064
205 0.727 +-0.055
235 0.750 +-0.044
265 0.444 +-0.040
295 0.248 +-0.026
325 0.242 +-0.029
365 0.247 +-0.025
405 0.139 +-0.015
465 8.66e-02 +-1.15e-02
525 3.75e-02 +-7.65e-03
605 2.38e-02 +-4.84e-03
725 7.21e-03 +-2.23e-03
885 2.16e-03 +-1.08e-03
1085 8.66e-04 +-4.72e-04
1285 1.73e-03 +-7.87e-04
1485 8.66e-04 +-7.64e-04
1685 0.00e+00 +-1.04e-03
1885 0.00e+00 +-6.67e-04
\END;
/*===================================================================*/
|