DARPE: Search Results
 /*===================================================================*/
 /* NRDF D1973 Data No.24                                             */
 /*===================================================================*/
 /* Bibliography                                                      */
 /*===================================================================*/
 \\BIB,24;
 D#=D1973;
 TITLE=/ Measurement of differential thick target neutron yields
         (TTY) from Fe, Cu(p,n) reactions at 35, 50, and 70 MeV /;
 ATH=(T.ITOGA'1', M.HAGIWARA'1', N.KAWATA'1', T.YAMAUCHI'1',
      N.HIRABAYASHI'1', T.OISHI'1', M.BABA'1');
 INST-ATH=(2JPNTOH'1');
      /* '1' Cyclotron and Radioisotope Center */
 REF=;
 VLP=;
 /* Secondary reference 
    - 2004SANTA, (2004)1568 (AIP Conf. Proc. Vol.769 part 2 published
      in May, 2005)
 RCTS=(FE(P,N)X, CU(P,N)X);
 PHQS=TTY;
 /*===================================================================*/
 /* Experimental Conditions                                           */
 /*===================================================================*/
 \\EXP,24;
 /* 2006-02-06 : Recieved, On. Data received by e-mail from T.Itoga
 /* 2006-02-07 : Compiled, Kc + On */
 PHQ=TTY;
 ENR=NAT;
 CHM=ELM;
 PHYS-FORM=SLD;
 THK-TGT=XMG/CM**2'2';
 /* '2' 30x30x3, 30x30x5 and 30x30x10 (mm) for 35, 50 and 70 MeV
        proton, respectively */
 POL-TGT=0%;
 ALGN-TGT=0%;
 ACC=CYC'3';
 /* '3' Isochronous cyclotron, AVF cyclotron */
 INST-ACC=2JPNTOH'4';
 /* '4' Cyclotron and Radioisotope Center */
 BEAM-INTNSTY=5[10NA;
 POL-PRJ=0%;
 DET-PARTCL=N;
 COINC=NO;
 ANT-COINC=NO;
 DET-SYS=(SCT'5',TOF);
 /* '5' To detect emitted neutron */
 /* Data have been corrected for the effect of (a) neutron attenuation
    in taget and (b) neutron attenuation in air. */
 /*===================================================================*/
 /* Descriptive Parameters                                            */
 /*===================================================================*/
 \\DATA,24;
 SYS-ERR=4%'6';
 /* '6' Uncertainty due to the estimation of detection efficiency
        by SCINFUL-R code */
 /*===================================================================*/
 /* Data Table                                                        */
 /*===================================================================*/
 \DATA;
 \END;
 /*===================================================================*/