/* NRDF D1773 Data No.24 */
/*===================================================================*/
/* Bibliography */
/*===================================================================*/
\\BIB,24;
D#=D1773;
TITLE=/CROSS SECTIONS AND POLARIZATION OBSERVABLES FOR THE 40CA(P,N)
REACTION AT 345 MEV AND MULTISTEP CONTRIBUTIONS IN THE
CONTINUUM/;
ATH=(T.WAKASA'1', K.HATANAKA'1', H.SAKAI'2,3', M.B.GREENFIELD'4',
J.KAMIYA'1', K.OGATA'1', H.OKAMURA'5', K.SEKIGUCHI'2',
K.SUDA'5', A.TAMII'2', K.YAKO'2');
INST-ATH=(2JPNRCN'1', 2JPNTOK'2', 2JPNIPC'3', 2JPNJPN'4', 2JPNJPN'5');
/* '2'DEPARTMENT OF PHYSICS */
/* '4'DIVISION OF NATURAL SCIENCES, INTERNATIONAL CHRISTIAN
UNIVERSITY, MITAKA, TOKYO */
/* '5'DEPARTMENT OF PHYSICS, SAITAMA UNIVERSITY, SAITAMA */
REF=PR/C;
VLP=65(2002)034615;
RCTS=40CA(P,N)X;
PHQS=(ENGY-SPEC, ANALPW, POL, POL-TRNSF);
/*===================================================================*/
/* Experimental Conditions */
/*===================================================================*/
\\EXP,24;
/* 2003-03-12 : COMPILED */
RTY=RRG-RCT;
ENR=NAT;
CHM=ELM;
PHYS-FORM=SLD;
BAC=SELF;
POL-TGT=0%;
ALGN-TGT=0%;
ACC=CYC'6';
/* '6' AVF AND RING CYCLOTRONS */
INST-ACC=2JPNRCN;
INC-ENGY-LAB=345MEV;
DELTA-INC-ENGY-LAB=1MEV;
POL-PRJ=70%'7';
/* '7' THE AVERAGE VALUE OF NORMAL COMPONENT OF THE BEAM POLARIZATION
WAS MEASURED AT THE BEAM LINE POLARIMETER 1(BLP1) LOCATED AFTER
THE RING CYCLOTRON. THE BLP1 CONSISTS OF FOUR PAIRS OF
CONJUGATE-ANGLE PLASTIC SCINTILLATORS. P(POLARIZED)+P ELASTIC
SCATTERING WAS USED AS THE ANALYZING REACTION, AND A
SELF-SUPPORTING CH2 TARGET WITH A THICKNESS OF 1.1MG/CM2 WAS USED
AS THE HYDROGEN TARGET. THE ELASTICALLY SCATTERED AND RECOIL
PROTONS WERE DETECTED IN KINEMATICAL COINCIDENCE WITH A PAIR OF
SCINTILLATORS. */
ION-SOURCE=/ POLARIZED ION SOURCE(HIGH INTENSITY POLARIZED ION SOURCE
(HIPIS [H.OKAMURA, NUCL. INSTRUM. METHODS PHYS. RES.
A443(2000)194].) /;
DET-PARTCL=N;
COINC=NO;
ANT-COINC=NO;
DET-SYS=(LIQUID-SCT,PLST-SCT,TOF);
EFCN-DET=/ THE NEUTRON DETECTION EFFICIENCY HAS BEEN DETERMINED BY
USING NEUTRONS FROM THE ZERO-DEGREE
7LI(P,N)7BE(G.S.+0.43MEV) REACTION AT THE SAME INCIDENT
ENERGY OF TP=345MEV. TOTAL DETECTION EFFECIENCY FOR ALL SIX
NEUTRON DETECTORS, TAKEN TOGETHER, BECOMES 0.14+-0.01,
WHERE THE UNCERTAINTY MAINLY COMES FROM THE UNCERTAINTIES
BOTH IN THE 7LI CROSS SECTION (3%) AND THE THICKNESS OF THE
7LI TARGET(3%). /;
ANL=DWBA'8';
/* '8' SEMICLASSICAL DISTORTED WAVE MODEL (SCDW) */
RCT=40CA(P,N)X;
PHQ=POL-TRNSF;
THK-TGT=669MG/CM**2;
ERS-PRJ=3MEV'78';
/* '78' TOTAL FULL WIDTH AT HALF MAXIMUM ENERGY RESOLUTION. */
BEAM-INTNSTY=50NA'79';
/* '79' TYPICAL VALUE */
DET-PARTCL=N;
/*===================================================================*/
/* Descriptive Parameters */
/*===================================================================*/
\\DATA,24;
INC-ENGY-LAB=345MEV;
EMT=N;
THTL=40DEG;
/*===================================================================*/
/* Data Table */
/*===================================================================*/
\DATA;
TRNSF-ENGY'80' POL-TRNSF DELTA-POL-TRNSF
(MEV) (NODIM) (NODIM)
32.50 -0.264 +-0.296
37.50 -0.085 +-0.228
42.50 -0.075 +-0.189
47.50 0.011 +-0.159
52.50 -0.146 +-0.136
57.50 0.092 +-0.117
62.50 0.048 +-0.104
67.50 -0.308 +-0.091
72.50 0.010 +-0.081
77.50 0.001 +-0.074
82.50 0.063 +-0.067
87.50 -0.003 +-0.061
92.50 0.017 +-0.056
97.50 0.054 +-0.052
102.50 0.014 +-0.049
107.50 0.044 +-0.047
112.50 0.085 +-0.044
117.50 0.013 +-0.043
122.50 -0.007 +-0.041
127.50 -0.002 +-0.040
132.50 -0.013 +-0.039
137.50 -0.027 +-0.038
142.50 0.067 +-0.037
147.50 -0.015 +-0.037
152.50 0.007 +-0.037
157.50 0.046 +-0.037
162.50 0.004 +-0.037
167.50 -0.049 +-0.037
172.50 0.035 +-0.038
177.50 0.040 +-0.039
182.50 0.050 +-0.040
187.50 -0.002 +-0.041
192.50 -0.018 +-0.043
197.50 0.076 +-0.045
\END;
/*===================================================================*/
|