|
| /*===================================================================*/
/* NRDF D1586 Data No.21 */
/*===================================================================*/
/* Bibliography */
/*===================================================================*/
\\BIB,21;
D#=D1586;
TITLE=/ Single-particle states in 59Ni with 58Ni(d,p)59Ni reaction
at 56 MeV and neutron-bound-state complex potentials /;
PURPOSE=/ To measure the cross sections and analyzing powers /;
ATH=(O.IWAMOTO'1', A.NOHTOMI'1', Y.UOZUMI'1', T.SAKAE'1', M.MATOBA'1',
M.NAKANO'2', T.MAKI'2', N.KOORI'3');
INST-ATH=(2JPNKYU'1', 2JPNKIT'2', 2JPNTKS'3');
/* '1' Department of Nuclear Engineering */
/* '2' School of Nursing and Technology */
/* '3' Faculty of Integrated Arts and Sciences */
REF=NP/A;
VLP=576(1994)387;
RCTS=58NI(D,P)59NI;
PHQS=(SPEC-FCTR, ANGL-DSTRN, VCTR-ANALPW, SPEC-FCTR'4');
/* '4' Sum of spectroscopic factor */
/*===================================================================*/
/* Experimental Conditions */
/*===================================================================*/
\\EXP,21;
/* 2005-09-24 : Converted, Sr + On. Converted to EXFOR E1586 */
/* 2005-11-07 : Altered, At + Kc + Sr. Re-digitized */
/* Related references
- N.Matsuoka et al., NP/A, 455(1986)413.
ENR=99.89%;
CHM=ELM;
PHYS-FORM=SLD;
THK-TGT=0.473MG/CM**2;
POL-TGT=0%;
ALGN-TGT=0%;
ACC=CYC'5';
/* '5' Isochronous cyclotron, AVF cyclotron */
INST-ACC=2JPNRCN;
INC-ENGY-LAB=56MEV;
POL-PRJ=[50%;
DET-PARTCL=P;
COINC=NO;
ANT-COINC=NO;
DET-SYS=MAG'6';
/* '6' Magnetic spectrograph RAIDEN [H.Ikegami, et al. Nucl.
Instr. Meth. 175(1980)33] with the focal-plane detector system
KYUSHYU [M.Matoba, et al. Nucl. Instr. Meth. 180(1981)419] */
ERS-DET=45KEV;
ANL=DWBA'7';
/* '7' Code DWUCK [P.D.Kunz, code DWUCK, University of Colorado
(unpublished)] */
RCT=58NI(D,P)59NI;
PHQ=VCTR-ANALPW;
/*===================================================================*/
/* Descriptive Parameters */
/*===================================================================*/
\\DATA,21;
INC-ENGY-LAB=56MEV;
SYS-ERR=X%'96';
/* '96' Uncertainty in run-to-run variations of the integrated
beam current are on the order of a few percent. */
EMT=P;
EXC-ENGY=1.305MEV;
J-PTY=1/2-;
TRNSF-L=1'97';
/* '97' Transferred angular momentum (L) */
TRNSF-J=1/2'98';
/* '98' Transferred spin (J) */
/*===================================================================*/
/* Data Table */
/*===================================================================*/
\DATA;
THTC AY DELTA-AY'99'
(DEG) (NODIM) (NODIM)
5.200E+00 -3.714E-01 +-4.324E-02
8.231E+00 -2.748E-01 +-5.405E-02
1.140E+01 -1.026E-01 +-3.784E-02
1.432E+01 1.184E-01 +-4.324E-02
1.746E+01 6.367E-02 +-4.865E-02
2.046E+01 -1.046E-01 +-5.946E-02
2.372E+01 -2.350E-01 +-5.946E-02
2.673E+01 -2.843E-01 +-5.946E-02
2.978E+01 -4.719E-02 +-6.486E-02
3.389E+01 2.978E-01 +-8.648E-02
3.781E+01 1.240E-01 +-9.189E-02
4.208E+01 -3.634E-01 +-9.729E-02
\END;
/*===================================================================*/
|