|
| /*===================================================================*/
/* NRDF D1586 Data No.20 */
/*===================================================================*/
/* Bibliography */
/*===================================================================*/
\\BIB,20;
D#=D1586;
TITLE=/ Single-particle states in 59Ni with 58Ni(d,p)59Ni reaction
at 56 MeV and neutron-bound-state complex potentials /;
PURPOSE=/ To measure the cross sections and analyzing powers /;
ATH=(O.IWAMOTO'1', A.NOHTOMI'1', Y.UOZUMI'1', T.SAKAE'1', M.MATOBA'1',
M.NAKANO'2', T.MAKI'2', N.KOORI'3');
INST-ATH=(2JPNKYU'1', 2JPNKIT'2', 2JPNTKS'3');
/* '1' Department of Nuclear Engineering */
/* '2' School of Nursing and Technology */
/* '3' Faculty of Integrated Arts and Sciences */
REF=NP/A;
VLP=576(1994)387;
RCTS=58NI(D,P)59NI;
PHQS=(SPEC-FCTR, ANGL-DSTRN, VCTR-ANALPW, SPEC-FCTR'4');
/* '4' Sum of spectroscopic factor */
/*===================================================================*/
/* Experimental Conditions */
/*===================================================================*/
\\EXP,20;
/* 2005-09-24 : Converted, Sr + On. Converted to EXFOR E1586 */
/* 2005-11-07 : Altered, At + Kc + Sr. Re-digitized */
/* Related references
- N.Matsuoka et al., NP/A, 455(1986)413.
ENR=99.89%;
CHM=ELM;
PHYS-FORM=SLD;
THK-TGT=0.473MG/CM**2;
POL-TGT=0%;
ALGN-TGT=0%;
ACC=CYC'5';
/* '5' Isochronous cyclotron, AVF cyclotron */
INST-ACC=2JPNRCN;
INC-ENGY-LAB=56MEV;
POL-PRJ=[50%;
DET-PARTCL=P;
COINC=NO;
ANT-COINC=NO;
DET-SYS=MAG'6';
/* '6' Magnetic spectrograph RAIDEN [H.Ikegami, et al. Nucl.
Instr. Meth. 175(1980)33] with the focal-plane detector system
KYUSHYU [M.Matoba, et al. Nucl. Instr. Meth. 180(1981)419] */
ERS-DET=45KEV;
ANL=DWBA'7';
/* '7' Code DWUCK [P.D.Kunz, code DWUCK, University of Colorado
(unpublished)] */
RCT=58NI(D,P)59NI;
PHQ=VCTR-ANALPW;
/*===================================================================*/
/* Descriptive Parameters */
/*===================================================================*/
\\DATA,20;
INC-ENGY-LAB=56MEV;
SYS-ERR=X%'92';
/* '92' Uncertainty in run-to-run variations of the integrated
beam current are on the order of a few percent. */
EMT=P;
EXC-ENGY=0.463MEV;
J-PTY=1/2-;
TRNSF-L=1'93';
/* '93' Transferred angular momentum (L) */
TRNSF-J=1/2'94';
/* '94' Transferred spin (J) */
/*===================================================================*/
/* Data Table */
/*===================================================================*/
\DATA;
THTC AY DELTA-AY'95'
(DEG) (NODIM) (NODIM)
5.220E+00 -5.227E-01 +-3.766E-02
8.249E+00 -5.072E-01 +-3.763E-02
1.122E+01 -1.261E-01 +-3.226E-02
1.433E+01 3.033E-01 +-3.763E-02
1.748E+01 2.811E-01 +-3.226E-02
2.057E+01 -6.904E-02 +-4.839E-02
2.364E+01 -5.052E-01 +-4.839E-02
2.684E+01 -3.124E-01 +-4.841E-02
2.981E+01 9.560E-02 +-5.376E-02
3.397E+01 5.087E-01 +-6.451E-02
3.800E+01 2.336E-01 +-7.527E-02
4.212E+01 -2.297E-01 +-9.677E-02
\END;
/*===================================================================*/
|