/* NRDF D1434 Data No.20 */
/*===================================================================*/
/* Bibliography */
/*===================================================================*/
\\BIB,20;
D#=D1434;
TITLE=/Nuclear structure of even lead isotopes by the (p,t) reaction/;
ATH=(M.TAKAHASHI'1', T.MURAKAMI'1', S.MORITA'1', H.ORIHARA'2',
Y.ISHIZAKI'3', H.YAMAGUCHI'4');
INST-ATH=(2JPNTOH'1', 2JPNTOH'2', 2JPNINS'3', 2JPNTKS'4');
/* '1' Department of Physics */
/* '2' Cyclotron and Radioisotope Center */
/* '3' Institute for Nuclear Study */
/* '4' Faculty of General Education */
REF=PR/C;
VLP=27(1983)1454;
RCTS=(208PB(P,T)206PB, 206PB(P,T)204PB, 204PB(P,T)202PB);
PHQS=ANGL-DSTRN;
/*===================================================================*/
/* Experimental Conditions */
/*===================================================================*/
\\EXP,20;
/* 2003-10-24 : Converted, Data converted to EXFOR E1434 and EXFOR
O0685 */
PHQ=ANGL-DSTRN;
ENR=>99%;
POL-TGT=0%;
ALGN-TGT=0%;
ACC=SYNCYC;
INST-ACC=2JPNINS;
INC-ENGY-LAB=51.9MEV;
POL-PRJ=0%;
DET-PARTCL=T;
COINC=NO;
ANT-COINC=NO;
DET-SYS=(MAG'5',PROP-CNTR'6',SCT);
/* '5' To analyze triton momentum */
/* '6' Array of 200 proportional counters serve as position
detectors. They form counter telescopes in combination with
scintillation counters. */
ERS-DET=[90KEV'7';
/* '7' Overall energy resolution for the tritons of interest */
ANL=DWBA'8';
/* '8' Zero-range DWBA approximation (code DWUCK-4, [W.A.Lanford
and J.B.McGrory, Michigan State University Cyclotron Laboratory
Report No.MSUCL-81, 1973 (unpublished); Phys. Lett.
45B(1973)283]) */
RCT=208PB(P,T)206PB;
CHM=ELM;
PHYS-FORM=SLD'97';
/* '97' Metallic foil */
THK-TGT=4MG/CM**2;
/*===================================================================*/
/* Descriptive Parameters */
/*===================================================================*/
\\DATA,20;
INC-ENGY-LAB=51.9MEV;
SYS-ERR=<20%'98';
/* '98' Error of the absolute cross section of the ground state
transition is estimated to be less than 20%, where the main
part comes from the uncertainty of the solid angle of each
counter on the focal plane of the magnetic spectrograph. */
EMT=T;
RSD=206PB;
EXC-ENGY=1.99MEV;
J-PTY=4+;
DELTA-THTC=0.25DEG'99';
/* '99' Data-point reader uncertainty */
DELTA-DSIGMA/DOMEGA=1.9%'100';
/* '100' Data-point reader uncertainty */
/*===================================================================*/
/* Data Table */
/*===================================================================*/
\DATA;
THTC DSIGMA/DOMEGA
(DEG) (UB/SR)
5.1 144.
7.89 117.3
10.49 91.2
12.88 81.7
15.26 82.
18.05 71.5
20.45 60.5
23.62 56.6
26.02 52.2
29.21 47.5
34. 26.7
38.59 19.2
43.78 13.36
48.56 8.79
53.74 6.77
58.52 5.13
63.91 3.02
\END;
/*===================================================================*/
|