|
| /*===================================================================*/
/* NRDF D1996 Data No.2 */
/*===================================================================*/
/* Bibliography */
/*===================================================================*/
\\BIB,2;
D#=D1996;
TITLE=/ Alpha beam monitoring via natCu + alpha processes in the
energy range from 40 to 60 MeV /;
ATH=(F.SZELECSENYI'1', K.SUZUKI'2', Z.KOVACS'1', M.TAKEI'2',
K.OKADA'2');
INST-ATH=(3HUNDEB'1', 2JPNIRS'2');
/* '1' Cyclotron Department */
/* '2' Division of Advanced Technology for Medical Imaging */
REF=NIM/B;
VLP=184(2001)589;
RCTS=(CU(ALPHA,X)61CU, CU(ALPHA,X)66GA, CU(ALPHA,X)67GA);
PHQS=XSECTN;
/*===================================================================*/
/* Experimental Conditions */
/*===================================================================*/
\\EXP,2;
/* 2006-09-06 : Compiled, Tk + On */
PHQ=XSECTN;
CHM=ELM;
PHYS-FORM=SLD;
POL-TGT=0%;
ALGN-TGT=0%;
ACC=CYC'3';
/* '3' Isochronous cyclotron, AVF cyclotron */
INST-ACC=2JPNIRS;
BEAM-INTNSTY=(94NA,96NA,183NA);
POL-PRJ=0%;
COINC=NO;
ANT-COINC=NO;
DET-SYS=HPGE'4';
/* '4' To determine activity of samples */
/* Experimental Method:
- Activation (Irradiated for 10, 20 and 30 min (3 runs))
- Stacked target irradiation (Stacks made up of natCu and natCo)
- Beam current integrated (Via electric charge collection in
Faraday cage)
/* Related references
- common, A0465007, J(Pram)31.
. See also EXFOR commo.n.
- Compared with present result, A0510376, B(Levk).
. See also EXFOR 109..
- Compared with present result, A0353003, J(Radi)39.
- Compared with present result, D4085003, J(Nucl)168.
. See also EXFOR 61..
RCT=CU(ALPHA,X)66GA;
INC-ENGY-LAB=15[59MEV;
DET-PARTCL=GAMMA'14';
/* '14' Delayed gamma from 66Ga */
/*===================================================================*/
/* Descriptive Parameters */
/*===================================================================*/
\\DATA,2;
TOT-ERR=12%;
SYS-ERR=(8%'5',5%'6',3%'7');
/* '5' Uncertainty in flux measurement */
/* '6' Uncertainty in detector efficiency */
/* '7' Uncertainty in nuclear data */
STATIST-ERR=<1%'8';
/* '8' Maximum uncertainty in counting statistics */
ENGY-GAMMA=(833.58KEV'15',1039.35KEV'16');
INTNSTY-GAMMA=(0.0603'15',0.3792'16');
HALF-LIFE=(9.49HOUR'16',9.49HOUR'15');
/* '15' Delayed gamma from 66Ga via NONe */
/* '16' Delayed gamma from 66Ga via NONe */
/*===================================================================*/
/* Data Table */
/*===================================================================*/
\DATA;
INC-ENGY-LAB DELTA-INC-ENGY-LAB'17' SIGMA DELTA-SIGMA
(MEV) (MEV) (MB) (MB)
15.9 +-1.9 466.7 +-51.0
19.2 +-1.7 479.4 +-52.8
20.8 +-2.6 146.9 +-16.2
22.3 +-1.6 271.7 +-29.9
25.1 +-1.5 140.0 +-15.6
25.7 +-2.3 70.3 +-7.8
27.7 +-1.3 57.5 +-6.4
28.9 +-2.2 38.0 +-4.2
30.0 +-1.2 32.3 +-3.5
32.1 +-2.0 49.3 +-5.5
32.3 +-1.1 39.3 +-4.3
34.2 +-1.9 82.3 +-9.1
34.4 +-1.0 64.1 +-7.1
35.3 +-1.8 98.8 +-10.8
36.5 +-0.9 97.5 +-10.8
37.9 +-1.7 133.7 +-14.7
38.3 +-1.7 128.8 +-14.3
40.3 +-0.7 153.2 +-17.0
41.1 +-1.5 152.9 +-16.9
41.2 +-1.5 157.5 +-17.3
43.7 +-1.4 158.1 +-17.3
44.5 +-1.4 146.9 +-16.2
46.8 +-1.3 131.8 +-14.5
47.6 +-1.2 126.4 +-13.9
49.9 +-1.1 92.4 +-10.2
50.6 +-1.1 91.2 +-10.1
52.7 +-1.0 75.5 +-8.4
53.3 +-0.9 71.7 +-7.9
55.4 +-0.8 85.0 +-10.1
56.0 +-0.8 54.9 +-6.1
58.1 +-0.7 45.3 +-5.0
\END;
/*===================================================================*/
|