/* NRDF D1890 Data No.2 */
/*===================================================================*/
/* Bibliography */
/*===================================================================*/
\\BIB,2;
D#=D1890;
TITLE=/ Precise measurement of the cross section of 3He(3He,2p)4He
by using 3He doubly charged beam /;
ATH=(N.KUDOMI'1', M.KOMORI'2', K.TAKAHISA'1', S.YOSHIDA'1', K.KUME'3',
H.OHSUMI'4', T.ITAHASHI'1');
INST-ATH=(2JPNRCN'1', 2JPNIRS'2', 2JPNWER'3', 2JPNJPN'4');
/* '4' Faculty of Culture and Education, Saga University, Saga
REF=PR/C;
VLP=69(2004)015802;
/* Secondary reference
- NP/A, 718(2003)466 (T.Itahashi et al., Proc. of the Seventh
International Symposium on Nuclei in the Cosmos (NIC7))
RCTS=3HE(3HE,2*P)4HE;
PHQS=(XSECTN, ASTR-SFCTR);
/*===================================================================*/
/* Experimental Conditions */
/*===================================================================*/
\\EXP,2;
/* 2004-04-16 : Compiled+Checked, C.Kurokawa + N.Otuka */
/* 2006-10-04 : Altered, N.Otuka. Reference (NIC7) added */
/* Related references
- T.Itahashi et al., RSI, 69(1998)1032.
(Performance and design of ion source)
- T.Itahashi et al., RSI, 71(2000)1075.
(Performance and design of ion source)
CHM=ELM;
PHYS-FORM=GAS'6';
/* '6' Windowless gas target consists of a differential pumping
and gas circulation/purification system */
THK-TGT=XMG/CM**2'7';
/* '7' 0.75 Torr */
POL-TGT=0%;
ALGN-TGT=0%;
ACC=X'8';
/* '8' Accelerator, NANOGUN ECR ion source with specially
designed ceramic insulator */
INST-ACC=2JPNOSA;
INC-ENGY-CM-RANGE=31.2[45.3KEV'9';
/* '9' Effective reaction energy has 0.15% error, taking into
account accuracy of 0.1% for acceleration voltage, 10% for
stopping power, and 0.09% for energy spread in target */
BEAM-INTNSTY=200UA;
CHRG-INC-ION=2+;
POL-PRJ=0%;
DET-PARTCL=(ALPHA,P);
COINC=(P,P,ALPHA);
ANT-COINC=NO;
DET-SYS=(SSD'10',SSD'11',EDE'12');
/* '10' Delta E counters with FWHM of 100-120 keV for 5.48 MeV
alpha particle */
/* '11' E counters with FWHM of 70-100 keV for 5.48 MeV alpha
particle */
/* '12' 4 delta E-E counter telescopes */
/* Related references
- A.Krauss et al., NP/A, 467(1987)273.
Reference with which data agree (The accuracy of both statistical
and systematic uncertainties of the present measurement is better
than that in this work.)
RCT=3HE(3HE,2*P)4HE;
PHQ=ASTR-SFCTR;
/*===================================================================*/
/* Descriptive Parameters */
/*===================================================================*/
\\DATA,2;
SYS-ERR=(0.15%'13',2%'14',1.3%'15',3%'16');
/* '13' Uncertainty in reaction energy */
/* '14' Uncertainty in beam intensity */
/* '15' Uncertainty in target density */
/* '16' Uncertainty in detection efficiency */
SYS-ERR=3.8%'17';
/* '17' Total systematic error */
/*===================================================================*/
/* Data Table */
/*===================================================================*/
\DATA;
INC-ENGY-CM ASTR-SFCTR DELTA-ASTR-SFCTR'18'
(KEV) (MEV*B) (MEV*B)
31.2 6.40 +-0.39
33.1 5.48 +-0.22
35.2 5.62 +-0.21
37.3 5.46 +-0.20
39.3 5.69 +-0.25
41.3 5.51 +-0.18
43.3 5.43 +-0.14
45.3 5.39 +-0.09
\END;
/*===================================================================*/
|