/* NRDF D1870 Data No.2 */
/*===================================================================*/
/* Bibliography */
/*===================================================================*/
\\BIB,2;
D#=D1870;
TITLE=/ On the neutrons from the 14N(d,n)15O reaction - II /;
PURPOSE=/ To extend the measured angular range of our previous work
on 14N(d,n)15O reaction to the more backward direction /;
ATH=(I.NONAKA'1', S.MORITA'1', N.KAWAI'1', T.ISHIMATSU'1',
K.TAKESHITA'1', Y.NAKAJIMA'1', N.TAKANO'1');
INST-ATH=(2JPNKYU'1');
/* '1' Department of Physics, Faculty of Science */
REF=JPJ;
VLP=12(1957)841;
RCTS=(2H(D,N)3HE, 14N(D,N)15O);
PHQS=(ANGL-DSTRN, XSECTN);
/*===================================================================*/
/* Experimental Conditions */
/*===================================================================*/
\\EXP,2;
/* 2004-02-19 : Compiled, Sr + On */
/* Related references
- J.L.Fowler et al., RMP, 28(1956)103.
Reference for monitor (Angular distribution for 2H(d,n)3He given in
Fig.16, p112 of this reference)
CHM=X'2';
/* '2' Deuterium gas mixed to nitrogen gas */
PHYS-FORM=GAS;
THK-TGT=XMG/CM**2'3';
/* '3' Pressures of deuterium gas and nitrogen gas are 4.3 cmHg
and 23.2 cmHg, respectively. */
POL-TGT=0%;
ALGN-TGT=0%;
ACC=VDG;
INST-ACC=2JPNKYU;
INC-ENGY-LAB=[1.96MEV'4';
/* '4' considering the energy loss of 190 keV in the nickel foil
(1.6mg/cm**2 thick) at the entrance of target chamber and that
of 320 keV in target gas */
BEAM-INTNSTY=1UA'5';
/* '5' average value */
POL-PRJ=0%;
DET-PARTCL=N;
COINC=NO;
ANT-COINC=NO;
DET-SYS=PLATE'6';
/* '6' Sakura NR-MI nuclear plates, 200 micron emulsion thickness
used to detect neutrons */
/* 2006-10-05 : Altered, Is. Re-digitized */
RCT=14N(D,N)15O;
PHQ=ANGL-DSTRN;
MONTR-RCT=/ 2H(D,N)3HE /;
ANL=X'9';
/* '9' Stripping theory [A.B.Bhatia et al., Phil. Mag.
43(1952)485] */
/*===================================================================*/
/* Descriptive Parameters */
/*===================================================================*/
\\DATA,2;
INC-ENGY-LAB=[1.96MEV'7';
/* '7' considering the energy loss of 190 keV in the nickel foil
(1.6mg/cm**2 thick) at the entrance of target chamber and that
of 320 keV in target gas */
/*===================================================================*/
/* Data Table */
/*===================================================================*/
\DATA;
THTC DSIGMA/DOMEGA DELTA-DSIGMA/DOMEGA'10'
(DEG) (MB/SR) (MB/SR)
4.971E-01 2.396E+00 +-3.197E-01
1.602E+01 3.080E+00 +-3.394E-01
3.241E+01 3.764E+00 +-4.193E-01
4.691E+01 2.490E+00 +-2.396E-01
6.253E+01 2.455E+00 +-2.995E-01
7.824E+01 1.861E+00 +-2.596E-01
9.349E+01 1.406E+00 +-1.997E-01
1.078E+02 1.511E+00 +-1.997E-01
1.220E+02 2.593E+00 +-3.195E-01
1.368E+02 4.874E+00 +-4.593E-01
1.515E+02 7.973E+00 +-6.389E-01
1.651E+02 1.045E+01 +-7.387E-01
\END;
/*===================================================================*/
|