/* NRDF D1825 Data No.2 */
/*===================================================================*/
/* Bibliography */
/*===================================================================*/
\\BIB,2;
D#=D1825;
TITLE=/ Isomeric 0+ state in 12Be /;
PURPOSE=/ To produce 12Be in the isomeric second 0+ state. /;
ATH=(S.SHIMOURA'1', A.SAITO'2', T.MINEMURA'3', Y.U.MATSUYAMA'2',
H.BABA'2', H.AKIYOSHI'3', N.AOI'4', T.GOMI'2', Y.HIGURASHI'2',
K.IEKI'2', N.IMAI'4', N.IWASA'5', H.IWASAKI'1', S.KANNO'2',
S.KUBONO'1', M.KUNIBU'2', S.MICHIMASA'1', T.MOTOBAYASHI'2',
T.NAKAMURA'6', H.SAKURAI'4', M.SERATA'2', E.TAKESHITA'2',
S.TAKEUCHI'2', T.TERANISHI'1', K.UE'1', K.YAMADA'2',
Y.YANAGISAWA'3', M.ISHIHARA'3', N.ITAGAKI'4');
INST-ATH=(2JPNTOK'1', 2JPNRIK'2', 2JPNIPC'3', 2JPNTOK'4', 2JPNTOH'5',
2JPNTIT'6');
/* '1' Center for Nuclear Study */
/* '2' Department of Physics */
/* '4' Department of Physics */
/* '5' Department of Physics */
/* '6' Department of Applied Physics */
REF=PL/B;
VLP=560(2003)31;
RCTS=9BE(18O,12BE)X;
PHQS=(ANGL-CORRL'7', ENGY-SPEC);
/* '7' Azimuthal angular correlation */
/*===================================================================*/
/* Experimental Conditions */
/*===================================================================*/
\\EXP,2;
/* 2003-10-08 : Compiled, Kc + Sr */
RTY=FRAG;
ENR=NAT;
CHM=ELM;
PHYS-FORM=SLD;
THK-TGT=2000MG/CM**2;
BAC=SELF;
POL-TGT=0%;
ALGN-TGT=0%;
ACC=CYC'8';
/* '8' RIKEN Ring Cyclotron */
INST-ACC=2JPNIPC;
INC-ENGY-LAB=100MEV/A;
POL-PRJ=0%;
COINC=(GAMMA,12BE);
ANT-COINC=NO;
DET-SYS=(SCT'9',NAI'10',EDE,TOF);
/* '9' The 12Be fragment after the isomeric decay was recorded by
a plastic scintillator hodoscope with a 1 x 1 m2 active area
located 4 m downstream of NaI scintillators (DALI). */
/* '10' NaI(Tl) scintillator. Gamma rays were detected by an
array of 68 NaI(Tl) scintillators (DALI) positioned at 70 cm
downstream of the F3 scintillator. Each NaI had an active
volume of 12 x 6 x 6 cm3. */
ERS-DET=XKEV'11';
/* '11' The energy threshold for each detector was set to be
lower than 50 keV. */
/* Experimental Method:
- Particle identification by 'E/Delta E' measurement
- Time-of-flight
- Coincidence
RCT=9BE(18O,12BE)X;
PHQ=ENGY-SPEC;
DET-PARTCL=(GAMMA'18',12BE);
/* '18' Prompt gamma from 12Be */
/*===================================================================*/
/* Descriptive Parameters */
/*===================================================================*/
\\DATA,2;
INC-ENGY-LAB=100MEV/A;
EMT-1=12BE;
ENGY-GAMMA=(0.14MEV'19',2.1MEV'20');
/* '19' Prompt gamma from 12Be via NONe */
/* '20' Prompt gamma from 12Be via NONe */
ENGY-EMT-1-LAB=60MEV/A;
EXC-ENGY-EMT-1=2.24MEV;
DELTA-EXC-ENGY-EMT-1=0.02MEV;
J-PTY-EMT-1=0+;
/*===================================================================*/
/* Data Table */
/*===================================================================*/
\DATA;
J-PTY-INITL J-PTY-FINAL EXC-ENGY DELTA-EXC-ENGY
(NODIM) (NODIM) (MEV) (MEV)
0+ 0+ 2.24 +-0.02
\END;
/*===================================================================*/
|