/* NRDF D1760 Data No.2 */
/*===================================================================*/
/* Bibliography */
/*===================================================================*/
\\BIB,2;
D#=D1760;
TITLE=/SPALLATION NEUTRON MEASUREMENT BY THE TIME-OF-FLIGHT METHOD
WITH A SHORT FLIGHT PATH/;
PURPOSE=/TO MEASURE THE DOUBLE DIFFERENTIAL CROSS SECTION ON PRODUCTION
OF THE SPALLATION NEUTRONS./;
ATH=(T.NAKAMOTO'1', K.ISHIBASHI'1', N.MATSUFUJI'1', N.SHIGYO'1',
K.MAEHATA'1', S.MEIGO'2', H.TAKADA'2', S.CHIBA'2',
M.NUMAJIRI'3', T.NAKAMURA'4', Y.WATANABE'5');
INST-ATH=(2JPNKYU'1', 2JPNJAE'2', 2JPNLEP'3', 2JPNTOH'4', 2JPNKYU'5');
/* '1'DEPARTMENT OF NUCLEAR ENGINEERING */
/* '4'CYCLOTRON RADIOISOTOPE CENTER */
/* '5'ENERGY CONVERSION ENGINEERING */
REF=NST;
VLP=32(1995)827;
RCTS=(C(P,N)X, PB(P,N)X);
PHQS=ENGY-SPEC;
/*===================================================================*/
/* Experimental Conditions */
/*===================================================================*/
\\EXP,2;
/* 2002-11-15 : COMPILED, AUTHOR (T.NAKAMOTO) RECOMMEND TO USE
DATA SET IN OTHER REFERENCE [NUCL.SCI.TECHNOL.34(1997)529]. */
RTY=SPAL;
PHQ=ENGY-SPEC;
ENR=NAT;
CHM=ELM;
PHYS-FORM=SLD;
POL-TGT=0%;
ALGN-TGT=0%;
ACC=SYN'6';
/* '6' THE PI-2 LINE OF THE 12 GEV PROTON SYNCHROTRON */
INST-ACC=2JPNLEP;
BEAM-INTNSTY=XMA'7';
/* '7' IN A LEVEL OF 100000 PROTONS / 2.5 S AT THE PI-2 BEAM LINE. */
POL-PRJ=0%;
ION-SOURCE=/ INCIDENT PROTONS WERE GENERATED AS SECONDARY BEAM. TOF
METHOD WITH A PAIR OF PILOT U SCINTILLATORS WAS ADOPTED
FOR SEPARATION BETWEEN PROTONS AND PIONS. /;
DET-PARTCL=N;
COINC=NO;
ANT-COINC=NO;
DET-SYS=(TOF,SCT'8',PLST-SCT'9');
/* '8' TWO DEFFERENT SIZES (DIAMETERXTHICK=5CMX5CM, 2CMX2CM) OF NE213
NEUTRON DETECTORS WERE PLACED IN THE DIRECTIONS OF 15 DEGREE, 30
DEGREE, 60 DEGREE, 90 DEGREE, 120 DEGREE AND 150 DEGREE */
/* '9' NE102A PLASTIC SCINTILLATORS WERE MOUNTED AS VETO DETECTORS TO
ELIMINATE CHARGED PARTICLE EVENTS BY THE ANTI-COINCIDENCE METHOD
ERS-DET=XKEV'10';
/* '10' THE ENERGY RESOLUTIONS IN ONE SIGMA WERE 5.7 % AT THE NEUTRON
ENERGY OF 10 MEV AND 14 % AT 300 MEV. */
EFCN-DET=/ THE UNCERTAINTY OF THE NEUTRON DETECTION EFFICIENCY RANGED
UP TO 10 % /;
RCT=C(P,N)X;
THK-TGT=20000MG/CM**2;
INC-ENGY-LAB=0.8GEV;
DET-PARTCL=N;
/*===================================================================*/
/* Descriptive Parameters */
/*===================================================================*/
\\DATA,2;
INC-ENGY-LAB=0.8GEV;
EMT=N;
THTL=60DEG;
/*===================================================================*/
/* Data Table */
/*===================================================================*/
\DATA;
ENGY-EMT-LAB DSIGMA/DOMEGA/DE DELTA-DSIGMA/DOMEGA/DE
(MEV) (B/SR/MEV) (B/SR/MEV)
1.2500 0.00054101 +-0.00013499
1.7500 0.00078493 +-0.00014741
2.5000 0.00048184 +-0.00010602
3.5000 0.00055838 +-0.00010300
4.5000 0.00054502 +-9.6332E-05
5.5000 0.00055483 +-0.00010383
7.0000 0.00042621 +-6.6886E-05
9.0000 0.00041771 +-5.9632E-05
12.500 0.00032820 +-4.0661E-05
17.500 0.00023045 +-3.2303E-05
25.000 0.00019731 +-2.6269E-05
35.000 0.00021811 +-3.0068E-05
45.000 0.00017234 +-2.8997E-05
55.000 0.00014678 +-2.5682E-05
70.000 0.00016315 +-2.2700E-05
90.000 0.00013323 +-1.9791E-05
125.00 9.3689E-05 +-1.2154E-05
175.00 4.5533E-05 +-7.5352E-06
250.00 2.1216E-05 +-3.4231E-06
350.00 4.0497E-06 +-1.6720E-06
\END;
/*===================================================================*/
|