/* NRDF D1642 Data No.2 */
/*===================================================================*/
/* Bibliography */
/*===================================================================*/
\\BIB,2;
D#=D1642;
TITLE=/ Strong mutual excitation of 148Nd+20Ne /;
PURPOSE=/ This paper reports a study of mutual excitation in
acolliding system that contains stronger couplings between
theelastic and inelastic channels /;
ATH=(C.L.JIANG'1', S.KUBONO'1', N.IKEDA'1', M.TANAKA'1',
H.KAWASHIMA'1', Y.FUCHI'1', I.KATAYAMA'1', T.NOMURA'1',
S.C.PIEPER'2');
INST-ATH=(2JPNINS'1', 1USAANL'2');
/* '2' Physics Division */
REF=PL/B;
VLP=259(1991)427;
RCTS=148ND(20NE,20NE)148ND;
PHQS=ANGL-DSTRN;
/*===================================================================*/
/* Experimental Conditions */
/*===================================================================*/
\\EXP,2;
/* 2003-10-02 : Converted, Kc + Am + On. Converted to EXFOR E1642
PHQ=ANGL-DSTRN;
ENR=93.2%'3';
/* '3' The effect of other neodymium isotopes has been considered
and eliminated. */
CHM=X'4';
/* '4' Enriched neodymium oxides */
PHYS-FORM=SLD;
THK-TGT=[0.005MG/CM**2;
BAC=C;
THK-BAC=[0.010MG/CM**2;
POL-TGT=0%;
ALGN-TGT=0%;
ACC=CYC'5';
/* '5' Sector-focussing cyclotron */
INST-ACC=2JPNINS;
INC-ENGY-LAB=116.0MEV;
BEAM-INTNSTY=1[2PNA;
CHRG-INC-ION=7+;
POL-PRJ=0%;
ION-SOURCE=/ ECR (Electron Cyclotron Resonance) ion source
[M.Sakiguchi et al., Proc. Intern. Conf. on ECR ion
sources and their applications, NSCL report MSUR47,
p323]. /;
DET-PARTCL=20NE;
COINC=NO;
ANT-COINC=NO;
DET-SYS=(MAG'6',SBD'7');
/* '6' Outgoing particles were analyzed magnetically and
identified with the QDD magnet spectrometer together with a
focal plane detector [S.Kato et al., Nucl. Instrum. Methods
154(1978)19. and M.Tanaka et al., Nucl. Instrum. Methods
195(1982)19.]. */
/* '7' Placed at 30 deg opposite to the spectrometer and served as
a monitor in the angular distribution measurement. */
SOLID-ANGL=2.0MSR;
ERS-DET=100[160KEV'8';
/* '8' Overall energy resolution in the measurement (depending
measuring angle) */
ANL=CC'9';
/* '9' PTOLEMY [PTOLEMY, Argonne report ANL-76-11, Rev.1,
unpublished] */
/* 2006-11-21 : Altered, At. Re-digitized */
RCT=148ND(20NE,20NE)148ND;
RTY=INEL-SCATT;
/*===================================================================*/
/* Descriptive Parameters */
/*===================================================================*/
\\DATA,2;
INC-ENGY-LAB=116.0MEV;
EXC-ENGY=0.301MEV;
J-PTY=2+;
EXC-ENGY-EMT=0.0MEV;
J-PTY-EMT=0+;
/*===================================================================*/
/* Data Table */
/*===================================================================*/
\DATA;
THTC DSIGMA/DOMEGA DELTA-DSIGMA/DOMEGA
(DEG) (MB/SR) (MB/SR)
1.847E+01 5.918E+02 +-2.435E+02
2.297E+01 4.416E+02 +-1.461E+02
2.765E+01 3.870E+02 +-7.223E+01
3.217E+01 3.470E+02 +-3.406E+01
3.645E+01 3.491E+02 +-2.489E+01
4.081E+01 3.203E+02 +-NEGLIGIBLE
4.532E+01 2.775E+02 +-NEGLIGIBLE
4.759E+01 2.931E+02 +-NEGLIGIBLE
4.976E+01 2.489E+02 +-NEGLIGIBLE
5.201E+01 2.162E+02 +-NEGLIGIBLE
5.419E+01 1.967E+02 +-NEGLIGIBLE
5.635E+01 1.406E+02 +-NEGLIGIBLE
5.860E+01 1.250E+02 +-NEGLIGIBLE
6.068E+01 7.878E+01 +-NEGLIGIBLE
6.284E+01 5.697E+01 +-NEGLIGIBLE
6.713E+01 2.040E+01 +-2.220E+00
7.128E+01 8.192E+00 +-1.318E+00
\END;
/*===================================================================*/
|