|
| /*===================================================================*/
/* NRDF D1370 Data No.2 */
/*===================================================================*/
/* Bibliography */
/*===================================================================*/
\\BIB,2;
D#=D1370;
TITLE=/ Pre-equilibrium process in 3He-induced reactions on 59Co,
109Ag, 181Ta and 209Bi /;
ATH=(Y.NAGAME'1', Y.NAKAMURA'2', M.TAKAHASHI'2', K.SUEKI'2',
H.NAKAHARA'2');
INST-ATH=(2JPNJAE'1', 2JPNTMU'2');
/* '1' Department of Radioisotopes */
/* '2' Department of Chemistry, Faculty of Science */
REF=NP/A;
VLP=486(1988)77;
RCTS=(59CO(3HE,N)61CU, 59CO(3HE,2*N)60CU, 59CO(3HE,2*N,2*P)58CO,
59CO(3HE,N,ALPHA)57CO, 59CO(3HE,2*N,ALPHA)56CO,
59CO(3HE,2*P)60CO, 109AG(3HE,N)111IN, 109AG(3HE,2*N)110IN,
109AG(3HE,3*N)109IN, 109AG(3HE,2*N,P)109CD, 209BI(3HE,N)211AT,
209BI(3HE,2*N)210AT, 209BI(3HE,3*N)209AT, 209BI(3HE,4*N)208AT,
209BI(3HE,2*N,ALPHA)206BI, 181TA(3HE,N)183RE);
PHQS=EXC-FUNCT;
/*===================================================================*/
/* Experimental Conditions */
/*===================================================================*/
\\EXP,2;
/* 2006-05-23 : Converted, N.Otuka. Converted to EXFOR E1370 */
PHQ=EXC-FUNCT;
CHM=ELM;
PHYS-FORM=SLD;
POL-TGT=0%;
ALGN-TGT=0%;
ACC=CYC;
INST-ACC=2JPNIPC;
BEAM-INTNSTY=[0.5UA;
POL-PRJ=0%;
COINC=NO;
ANT-COINC=NO;
ANL=PREEQUI-MODEL'3';
/* '3' Code ALICE /LIVERMORE /85 /300 */
/* Experimental Method:
- Stacked target irradiation (Constructed by targets and Al
catcher foils)
/* 2006-06-09 : Altered, Is. Re-digitized */
RCT=59CO(3HE,2*N)60CU;
THK-TGT=5[10MG/CM**2;
DET-PARTCL=GAMMA'13';
/* '13' Delayed gamma from 60Cu */
DET-SYS=GE(LI)'14';
/* '14' To measure radioactivities */
/* Experimental Method:
- Chemical separation
- Gamma ray spectrometry
/*===================================================================*/
/* Descriptive Parameters */
/*===================================================================*/
\\DATA,2;
SYS-ERR=(2%'4',5%'5',3%'6',20%'7',8%'8');
/* '4' Uncertainty in current integration with a Faraday cup */
/* '5' Maximum uncertainty in target thickness (2-5%) */
/* '6' Uncertainty in detector efficiency */
/* '7' Maximum uncertainty in gamma- or alpha-ray peak analysis */
/* '8' Uncertainty in chemical yield */
ENGY-GAMMA=1792KEV'15';
INTNSTY-GAMMA=0.454'15';
HALF-LIFE=23.4MIN'15';
/* '15' Delayed gamma from 60Cu */
/*===================================================================*/
/* Data Table */
/*===================================================================*/
\DATA;
INC-ENGY-LAB SIGMA
(MEV) (MB)
1.064E+01 5.498E+00
1.291E+01 3.944E+01
1.526E+01 6.499E+01
1.689E+01 1.216E+02
1.787E+01 1.021E+02
1.900E+01 1.126E+02
2.122E+01 6.457E+01
2.184E+01 5.508E+01
2.530E+01 2.969E+01
2.574E+01 2.413E+01
2.874E+01 1.706E+01
3.183E+01 1.225E+01
3.430E+01 9.225E+00
3.667E+01 7.892E+00
3.835E+01 6.963E+00
\END;
/*===================================================================*/
|