/* NRDF D1773 Data No.17 */
/*===================================================================*/
/* Bibliography */
/*===================================================================*/
\\BIB,17;
D#=D1773;
TITLE=/CROSS SECTIONS AND POLARIZATION OBSERVABLES FOR THE 40CA(P,N)
REACTION AT 345 MEV AND MULTISTEP CONTRIBUTIONS IN THE
CONTINUUM/;
ATH=(T.WAKASA'1', K.HATANAKA'1', H.SAKAI'2,3', M.B.GREENFIELD'4',
J.KAMIYA'1', K.OGATA'1', H.OKAMURA'5', K.SEKIGUCHI'2',
K.SUDA'5', A.TAMII'2', K.YAKO'2');
INST-ATH=(2JPNRCN'1', 2JPNTOK'2', 2JPNIPC'3', 2JPNJPN'4', 2JPNJPN'5');
/* '2'DEPARTMENT OF PHYSICS */
/* '4'DIVISION OF NATURAL SCIENCES, INTERNATIONAL CHRISTIAN
UNIVERSITY, MITAKA, TOKYO */
/* '5'DEPARTMENT OF PHYSICS, SAITAMA UNIVERSITY, SAITAMA */
REF=PR/C;
VLP=65(2002)034615;
RCTS=40CA(P,N)X;
PHQS=(ENGY-SPEC, ANALPW, POL, POL-TRNSF);
/*===================================================================*/
/* Experimental Conditions */
/*===================================================================*/
\\EXP,17;
/* 2003-03-12 : COMPILED */
RTY=RRG-RCT;
ENR=NAT;
CHM=ELM;
PHYS-FORM=SLD;
BAC=SELF;
POL-TGT=0%;
ALGN-TGT=0%;
ACC=CYC'6';
/* '6' AVF AND RING CYCLOTRONS */
INST-ACC=2JPNRCN;
INC-ENGY-LAB=345MEV;
DELTA-INC-ENGY-LAB=1MEV;
POL-PRJ=70%'7';
/* '7' THE AVERAGE VALUE OF NORMAL COMPONENT OF THE BEAM POLARIZATION
WAS MEASURED AT THE BEAM LINE POLARIMETER 1(BLP1) LOCATED AFTER
THE RING CYCLOTRON. THE BLP1 CONSISTS OF FOUR PAIRS OF
CONJUGATE-ANGLE PLASTIC SCINTILLATORS. P(POLARIZED)+P ELASTIC
SCATTERING WAS USED AS THE ANALYZING REACTION, AND A
SELF-SUPPORTING CH2 TARGET WITH A THICKNESS OF 1.1MG/CM2 WAS USED
AS THE HYDROGEN TARGET. THE ELASTICALLY SCATTERED AND RECOIL
PROTONS WERE DETECTED IN KINEMATICAL COINCIDENCE WITH A PAIR OF
SCINTILLATORS. */
ION-SOURCE=/ POLARIZED ION SOURCE(HIGH INTENSITY POLARIZED ION SOURCE
(HIPIS [H.OKAMURA, NUCL. INSTRUM. METHODS PHYS. RES.
A443(2000)194].) /;
DET-PARTCL=N;
COINC=NO;
ANT-COINC=NO;
DET-SYS=(LIQUID-SCT,PLST-SCT,TOF);
EFCN-DET=/ THE NEUTRON DETECTION EFFICIENCY HAS BEEN DETERMINED BY
USING NEUTRONS FROM THE ZERO-DEGREE
7LI(P,N)7BE(G.S.+0.43MEV) REACTION AT THE SAME INCIDENT
ENERGY OF TP=345MEV. TOTAL DETECTION EFFECIENCY FOR ALL SIX
NEUTRON DETECTORS, TAKEN TOGETHER, BECOMES 0.14+-0.01,
WHERE THE UNCERTAINTY MAINLY COMES FROM THE UNCERTAINTIES
BOTH IN THE 7LI CROSS SECTION (3%) AND THE THICKNESS OF THE
7LI TARGET(3%). /;
ANL=DWBA'8';
/* '8' SEMICLASSICAL DISTORTED WAVE MODEL (SCDW) */
RCT=40CA(P,N)X;
PHQ=ANALPW;
THK-TGT=359MG/CM**2;
ERS-PRJ=2MEV'57';
/* '57' TOTAL FULL WIDTH AT HALF MAXIMUM ENERGY RESOLUTION. */
BEAM-INTNSTY=10NA'58';
/* '58' TYPICAL VALUE */
DET-PARTCL=N;
/*===================================================================*/
/* Descriptive Parameters */
/*===================================================================*/
\\DATA,17;
INC-ENGY-LAB=345MEV;
TOT-ERR=[10%;
SYS-ERR=[8%;
STATIST-ERR=[2%;
EMT=N;
THTL=60DEG;
/*===================================================================*/
/* Data Table */
/*===================================================================*/
\DATA;
TRNSF-ENGY'59' ANALPW DELTA-ANALPW
(MEV) (NODIM) (NODIM)
27.50 0.074 +-0.077
32.50 0.070 +-0.081
37.50 0.193 +-0.076
42.50 0.156 +-0.072
47.50 0.281 +-0.068
52.50 0.176 +-0.065
57.50 0.199 +-0.058
62.50 0.199 +-0.053
67.50 0.217 +-0.048
72.50 0.220 +-0.044
77.50 0.239 +-0.039
82.50 0.287 +-0.036
87.50 0.225 +-0.034
92.50 0.234 +-0.030
97.50 0.151 +-0.029
102.50 0.176 +-0.027
107.50 0.175 +-0.025
112.50 0.244 +-0.023
117.50 0.208 +-0.021
122.50 0.210 +-0.020
127.50 0.221 +-0.018
132.50 0.200 +-0.017
137.50 0.193 +-0.016
142.50 0.177 +-0.016
147.50 0.184 +-0.015
152.50 0.172 +-0.014
157.50 0.174 +-0.013
162.50 0.180 +-0.013
167.50 0.162 +-0.012
172.50 0.157 +-0.012
177.50 0.134 +-0.012
182.50 0.137 +-0.011
187.50 0.121 +-0.011
192.50 0.095 +-0.011
197.50 0.109 +-0.011
\END;
/*===================================================================*/
|