/* NRDF D1912 Data No.16 */
/*===================================================================*/
/* Bibliography */
/*===================================================================*/
\\BIB,16;
D#=D1912;
TITLE=/ Isovector and isoscalar spin-flip M1 strengths in 11B /;
ATH=(T.KAWABATA'1', H.AKIMUNE'2', H.FUJIMURA'3', H.FUJITA'4',
Y.FUJITA'5', M.FUJIWARA'6,7', K.HARA'8', K.Y.HARA'2',
K.HATANAKA'6', T.ISHIKAWA'9', M.ITOH'6', J.KAMIYA'10', S.KISHI'3',
M.NAKAMURA'11', K.NAKANISHI'6', T.NORO'12', H.SAKAGUCHI'3',
Y.SHIMBARA'6', H.TAKEDA'13', A.TAMII'6', S.TERASHIMA'3',
H.TOYOKAWA'14', M.UCHIDA'3', H.UENO'13', T.WAKASA'12',
Y.YASUDA'3', H.P.YOSHIDA'6', M.YOSOI'3');
INST-ATH=(2JPNTOK'1', 2JPNKON'2', 2JPNKTO'3', 3SAFWIT'4', 2JPNOSA'5',
2JPNRCN'6', 2JPNJAE'7', 2JPNKEK'8', 2JPNTOH'9', 2JPNJAE'10',
2JPNJPN'11', 2JPNKYU'12', 2JPNIPC'13', 2JPNJSR'14');
/* '1' Center for Nuclear Study (CNS) */
/* '2' Department of Physics */
/* '3' Department of Physics */
/* '4' School of Physics */
/* '5' Department of Physics */
/* '7' Advanced Photon Research Center */
/* '9' Laboratory of Nuclear Science */
/* '11' Wakayama Medical University, Wakayama */
/* '12' Department of Physics */
REF=PR/C;
VLP=70(2004)034318;
RCTS=(11B(3HE,T)11C, 11B(D,D)11B, 12C(D,D)12C, 11B(P,P)11B);
PHQS=(ANGL-DSTRN, VCTR-ANALPW, TNSR-ANALPW, POL'15', POL-TRNSF'16',
OPT-POTL-PARA);
/* '15' Induced polarization */
/* '16' Polarization transfer coefficient */
/*===================================================================*/
/* Experimental Conditions */
/*===================================================================*/
\\EXP,16;
/* 2005-03-10 : Compiled, Kc + On */
ENR=X%'17';
/* '17' Contamining impurities in the 11B target were identified
by the kinematic energy shift in the elastic scattering at
backward angles, and those contributions were estimated to be
less than 1, 0.8 and 0.08 % for 10B, 12C and 16O,
respectively. */
CHM=ELM;
PHYS-FORM=SLD;
POL-TGT=0%;
ALGN-TGT=0%;
ACC=CYC;
INST-ACC=2JPNRCN;
BEAM-INTNSTY=1[10PNA;
POL-PRJ=X%'18';
/* '18' 200-MeV polarized deuteron and 392-MeV polarized proton
beams were used. Both beams were obtaned from the
high-intensity polarized ion source [ K.Hatanaka et al., Nucl.
Instrum. Methods Phs, Res. A 384(1997)575]. */
ION-SOURCE=/ Polarized ion source /;
COINC=NO;
ANT-COINC=NO;
DET-SYS=(MAG'19',MWDC'19',SCT'19');
/* '19' Grand Raiden [M.Fujiwara et al., Nucl. Instrum. Methods
Phys. Res. A 422(1999)484] for momentum analisis */
ANL=DWIA'20';
/* '20' Using a computer code DWBA98 */
RCT=12C(D,D)12C;
RTY=ELA-SCATT;
PHQ=ANGL-DSTRN;
THK-TGT=30.0MG/CM**2;
BAC=SELF;
INC-ENGY-LAB=200MEV;
DET-PARTCL=D;
/*===================================================================*/
/* Descriptive Parameters */
/*===================================================================*/
\\DATA,16;
INC-ENGY-LAB=200MEV;
EMT=D;
/*===================================================================*/
/* Data Table */
/*===================================================================*/
\DATA;
THTC DSIGMA/DOMEGA DELTA-DSIGMA/DOMEGA'48'
(DEG) (MB/SR) (MB/SR)
3.549 2926.651 +-81.595
4.731 2685.609 +-78.647
5.323 2792.360 +-61.817
6.505 2223.912 +-53.751
7.687 1675.122 +-15.172
8.869 1144.349 +-10.840
10.050 643.077 +-4.147
11.231 379.029 +-2.645
12.411 189.422 +-1.780
13.590 102.941 +-1.094
14.769 50.018 +-0.633
15.948 34.326 +-0.490
17.125 29.077 +-0.257
18.302 25.726 +-0.223
20.065 19.640 +-0.163
21.239 15.884 +-0.135
22.999 9.153 +-0.100
24.171 6.590 +-0.078
25.926 3.631 +-0.055
27.095 2.576 +-0.044
28.846 1.537 +-0.031
30.012 1.207 +-0.026
\END;
/*===================================================================*/
|