/* NRDF D1849 Data No.16 */
/*===================================================================*/
/* Bibliography */
/*===================================================================*/
\\BIB,16;
D#=D1849;
TITLE=/Some evidence for neutron pick-up from the interior core
through the (p,d) reaction/;
ATH=(T.ISHIMATSU'1', S.HAYASHIBE'1', N.KAWAMURA'1', T.AWAYA'2',
H.OHMURA'2', Y.NAKAJIMA'3', S.MITARAI'3');
INST-ATH=(2JPNTOH'1', 2JPNTOK'2', 2JPNKYU'3');
/* '1' Department of Physics */
/* '2' Department of Physics */
/* '3' Department of Physics */
REF=NP/A;
VLP=185(1972)273;
RCTS=(100MO(P,D)99MO, 94MO(P,D)93MO, 98MO(P,D)97MO);
PHQS=ANGL-DSTRN;
/*===================================================================*/
/* Experimental Conditions */
/*===================================================================*/
\\EXP,16;
/* 2003-10-31 : Converted, Data converted from EXFOR O0586 */
PHQ=ANGL-DSTRN;
CHM=ELM;
PHYS-FORM=SLD'4';
/* '4' Metallic foils */
POL-TGT=0%;
ALGN-TGT=0%;
ACC=SYNCYC;
INST-ACC=2JPNINS;
INC-ENGY-LAB=52MEV;
POL-PRJ=0%;
DET-PARTCL=D;
COINC=NO;
ANT-COINC=NO;
DET-SYS=(MAG'5',PROP-CNTR'6',PLST-SCT);
/* '5' Broad-range magnetic spectrometer [K.Yagi et al., Nucl.
Instr. 52(1967)29] */
/* '6' 200 proportional counters along the focal plane followed by
a plastic scintillation counter with 6 phototubes */
/* Experimental Method:
- Pulse-height discrimination (Aluminium foils placed in tront of
proportional counters and a pulse-height discriminator for the
outputs from the scintillation counters allowed the elimination
of triton backgrounds from deuteron spectra.)
RCT=100MO(P,D)99MO;
ENR=95.9%;
THK-TGT=3.0MG/CM**2;
/* Analysis:
- Integration of energy distribution (Integration of angular
distributions over the levels in the residual nuclei in a range
of excitation from 1.8 to 6.0 MeV)
/*===================================================================*/
/* Descriptive Parameters */
/*===================================================================*/
\\DATA,16;
INC-ENGY-LAB=52MEV;
SYS-ERR=(10%'79',X%'80');
/* '79' Uncertainty in the solid angle of spectrometer */
/* '80' Uncertainties in the absolute cross sections are
estimated to be less than +-20%. */
EMT=D;
RSD=99MO;
EXC-ENGY=1.8[6.0MEV;
DELTA-EXC-ENGY=0.02MEV;
DELTA-THTL=0.21DEG'81';
/* '81' Data-point reader uncertainty */
DELTA-DSIGMA/DOMEGA=1.6%'82';
/* '82' Data-point reader uncertainty */
/*===================================================================*/
/* Data Table */
/*===================================================================*/
\DATA;
THTL DSIGMA/DOMEGA
(DEG) (MB/SR)
5.21 25.2
8.35 23.1
11.31 19.2
14.25 14.85
17.06 12.32
19.9 11.19
22.85 9.08
25.78 6.65
29.98 3.79
33.72 3.36
38.38 3.22
42.51 2.38
46.16 1.59
50.48 1.345
54.23 1.233
\END;
/*===================================================================*/
|