/* NRDF D1759 Data No.16 */
/*===================================================================*/
/* Bibliography */
/*===================================================================*/
\\BIB,16;
D#=D1759;
TITLE=/ Measurements of secondary neutrons produced from thick
targets bombarded by high energy neon ions /;
PURPOSE=/ To perform a systematic study to measure the angular and
energy distributions of neutrons produced from thick C, Al,
Cu, and Pb targets bombarded by 100, 180 and 400 MeV/nucleon
Ne ions. /;
ATH=(T.KUROSAWA'1', N.NAKAO'2', T.NAKAMURA'1', Y.UWAMINO'3',
T.SHIBATA'2', A.FUKUMURA'4', K.MURAKAMI'4');
INST-ATH=(2JPNTOH'1', 2JPNKEK'2', 2JPNIPC'3', 2JPNIRS'4');
/* '1' Cyclotron and Radioisotope Center */
REF=NST;
VLP=36(1999)41;
RCTS=(C(20NE,N)X, 27AL(20NE,N)X, CU(20NE,N)X, PB(20NE,N)X);
PHQS=(ENGY-SPEC, N-MLT'5');
/* '5' Thick target differential multiplicity of neutron with
respect to angle integrated over partial angular range */
/*===================================================================*/
/* Experimental Conditions */
/*===================================================================*/
\\EXP,16;
/* 2002-02-24 : Compiled+Checked, R.Suzuki + sK */
/* 2004-04-23 : Altered, N.Otuka. MLT in SF6 replaced by PY */
/* 2008-01-30 : Altered, N.Otuka. EDE added under METHOD */
/* 2009-08-23 : Altered, Nf. 014-017 corrected */
RTY=HEAVY-ION-RCT;
ENR=NAT'6';
/* '6' The enrichments of targets are not given in the reference.
But compiler asked T.Kurosawa. */
CHM=ELM;
PHYS-FORM=SLD;
BAC=X;
POL-TGT=0%;
ALGN-TGT=0%;
ACC=SYN'7';
/* '7' Heavy Ion Medical Accelerator in Chiba (HIMAC) */
INST-ACC=2JPNIRS'8';
/* '8' The mass numbers of projectiles are not given in the
reference. But compiler asked NIRS staff. */
BEAM-INTNSTY=XMA'9';
/* '9' The beam intensities were kept to be 100,000-1,000,000
particles per pulse. */
POL-PRJ=0%;
DET-PARTCL=N;
COINC=NO;
ANT-COINC=NO;
DET-SYS=(SCT'10',SCT'11',TOF'12',EDE'13');
/* '10' Plastic scintillator (NE102A) was used as the delta-E
counter and the beam pick-up counter. Liquid scintillator
(NE213) was used as the E counter. */
/* '11' Liquid scintillator */
/* '12' To measure the energy of neutron */
/* '13' To eliminate charged particles */
ERS-DET=XKEV'14';
/* '14' The neutron energy resolutions is represented as a
function of neutron energy at Fig. 2 in reference. */
CALB-DET=/ Each E counter was calibrated with a 60Co Gamma-ray source.
EFCN-DET=/ The neutron detection efficiencies were calculated with the
Monte Carlo code of Cecil et al. for all energy ranges.
Reference: R. A. Cecil, B. D. Anderson, and R. Madey, Nucl.
Instrum. Methods 161, 439 (1979). /;
/* 2006-10-13 : Altered, Mh + N.Otuka. Re-digitized, and SF6 and 8
corrected */
/* 2009-08-23 : Altered, Nf. SF5=PAR and E-MIN=5 MeV added */
RCT=PB(20NE,N)X;
PHQ=N-MLT'50';
/* '50' Thick target differential multiplicity of neutron with
respect to angle integrated over partial angular range */
THK-TGT=XMG/CM**2'51';
/* '51' 5670 mg/cm**2 for 100MeV/nucleon Ne ions, 11340 mg/cm**2
for 180MeV/nucleon Ne ions, and 34020 mg/cm**2 for
400MeV/nucleon Ne ions. */
INC-ENGY-LAB-RANGE=(100MEV/A, 180MEV/A, 400MEV/A);
/* Analysis:
- Integration of energy distribution
- Integration of angular distribution
/*===================================================================*/
/* Descriptive Parameters */
/*===================================================================*/
\\DATA,16;
SYS-ERR=(3%'15',10%'16',8%'17',14%'18');
/* '15' Notmalization uncertainty due to number of accepted beam
particles incident on target */
/* '16' Normalization uncertainty due to solid angle uncertainty
/* '17' Normalization uncertainty due to additional uncertainty
in the efficiencies at neutron energies near threshold (8% in
Table 2, but 7% in text) */
/* '18' Total normalization uncertainty */
STATIST-ERR=X%'19';
/* '19' The statistical uncertainties vary in a range of 2 to 5 %
for the low- to medium-energy (5-50 MeV) region of the spectra
and increase to about 30% at the highest energies. */
ENGY-EMT-LAB=>5MEV;
THTL-MIN=0DEG;
THTL-MAX=90DEG;
/*===================================================================*/
/* Data Table */
/*===================================================================*/
\DATA;
INC-ENGY-LAB YLD
(MEV/A) (UNIT)
100 2.331E-01
180 8.577E-01
400 5.097E+00
\END;
/*===================================================================*/
|