/* NRDF D1370 Data No.16 */
/*===================================================================*/
/* Bibliography */
/*===================================================================*/
\\BIB,16;
D#=D1370;
TITLE=/ Pre-equilibrium process in 3He-induced reactions on 59Co,
109Ag, 181Ta and 209Bi /;
ATH=(Y.NAGAME'1', Y.NAKAMURA'2', M.TAKAHASHI'2', K.SUEKI'2',
H.NAKAHARA'2');
INST-ATH=(2JPNJAE'1', 2JPNTMU'2');
/* '1' Department of Radioisotopes */
/* '2' Department of Chemistry, Faculty of Science */
REF=NP/A;
VLP=486(1988)77;
RCTS=(59CO(3HE,N)61CU, 59CO(3HE,2*N)60CU, 59CO(3HE,2*N,2*P)58CO,
59CO(3HE,N,ALPHA)57CO, 59CO(3HE,2*N,ALPHA)56CO,
59CO(3HE,2*P)60CO, 109AG(3HE,N)111IN, 109AG(3HE,2*N)110IN,
109AG(3HE,3*N)109IN, 109AG(3HE,2*N,P)109CD, 209BI(3HE,N)211AT,
209BI(3HE,2*N)210AT, 209BI(3HE,3*N)209AT, 209BI(3HE,4*N)208AT,
209BI(3HE,2*N,ALPHA)206BI, 181TA(3HE,N)183RE);
PHQS=EXC-FUNCT;
/*===================================================================*/
/* Experimental Conditions */
/*===================================================================*/
\\EXP,16;
/* 2006-05-23 : Converted, N.Otuka. Converted to EXFOR E1370 */
PHQ=EXC-FUNCT;
CHM=ELM;
PHYS-FORM=SLD;
POL-TGT=0%;
ALGN-TGT=0%;
ACC=CYC;
INST-ACC=2JPNIPC;
BEAM-INTNSTY=[0.5UA;
POL-PRJ=0%;
COINC=NO;
ANT-COINC=NO;
ANL=PREEQUI-MODEL'3';
/* '3' Code ALICE /LIVERMORE /85 /300 */
/* Experimental Method:
- Stacked target irradiation (Constructed by targets and Al
catcher foils)
/* 2006-06-09 : Altered, Is. Re-digitized */
/* Related references
- N.E.Scott et al., NP/A, 119(1968)131.
(Compared but no comment by authors). See also EXFOR R0053.019.
RCT=181TA(3HE,N)183RE;
THK-TGT=[2MG/CM**2;
ACC=CYC;
INST-ACC=2JPNTOK'57';
/* '57' Instutite for Nuclear Study */
DET-PARTCL=GAMMA'58';
/* '58' Delayed gamma from 183Re */
DET-SYS=GE(LI)'59';
/* '59' To measure radioactivities */
/* Experimental Method:
- Gamma ray spectrometry
/*===================================================================*/
/* Descriptive Parameters */
/*===================================================================*/
\\DATA,16;
SYS-ERR=(2%'4',5%'5',3%'6',20%'7',8%'8');
/* '4' Uncertainty in current integration with a Faraday cup */
/* '5' Maximum uncertainty in target thickness (2-5%) */
/* '6' Uncertainty in detector efficiency */
/* '7' Maximum uncertainty in gamma- or alpha-ray peak analysis */
/* '8' Uncertainty in chemical yield */
ENGY-GAMMA=162KEV'60';
INTNSTY-GAMMA=0.235'60';
HALF-LIFE=70DAY'60';
/* '60' Delayed gamma from 183Re */
/*===================================================================*/
/* Data Table */
/*===================================================================*/
\DATA;
INC-ENGY-LAB SIGMA
(MEV) (MB)
1.771E+01 1.094E-01
1.973E+01 3.211E-01
2.147E+01 4.225E-01
2.347E+01 6.045E-01
2.515E+01 7.583E-01
2.625E+01 8.143E-01
2.850E+01 8.432E-01
3.018E+01 8.128E-01
3.140E+01 8.833E-01
3.288E+01 8.618E-01
3.430E+01 8.510E-01
3.572E+01 8.204E-01
3.707E+01 6.851E-01
3.817E+01 7.357E-01
3.990E+01 5.926E-01
4.248E+01 5.642E-01
4.583E+01 7.072E-01
4.899E+01 5.761E-01
5.214E+01 5.892E-01
5.491E+01 5.884E-01
5.807E+01 5.275E-01
6.187E+01 4.616E-01
6.374E+01 3.762E-01
\END;
/*===================================================================*/
|