/* NRDF D1921 Data No.13 */
/*===================================================================*/
/* Bibliography */
/*===================================================================*/
\\BIB,13;
D#=D1921;
TITLE=/ Activation cross-sections of long-lived products of
proton-induced nuclear reactions on zinc /;
ATH=(F.TARKANYI'1', F.DITROI'1', J.CSIKAI'1,2', S.TAKACS'1',
M.S.UDDIN'3', M.HAGIWARA'3', M.BABA'3', YU.N.SHUBIN'4',
A.I.DITYUK'4');
INST-ATH=(3HUNDEB'1', 3HUNKOS'2', 2JPNTOH'3', 4RUSFEI'4');
/* '2' Institute of Experimental Physics */
/* '3' Cyclotron and Radioisotope Center */
REF=ARI;
VLP=62(2005)73;
RCTS=(ZN(P,X)66GA, ZN(P,X)67GA, ZN(P,X)62ZN, ZN(P,X)65ZN,
ZN(P,X)69ZN, ZN(P,X)64CU, ZN(P,X)57NI, ZN(P,X)55CO, ZN(P,X)56CO,
ZN(P,X)57CO, ZN(P,X)58CO, ZN(P,X)60CO, ZN(P,X)52MN,
ZN(P,X)54MN);
PHQS=XSECTN;
/*===================================================================*/
/* Experimental Conditions */
/*===================================================================*/
\\EXP,13;
/* 2005-07-01 : Compiled, Tk + On. */
PHQ=XSECTN;
ENR=NAT;
CHM=ELM;
PHYS-FORM=SLD'5';
/* '5' Stacked with Cu (50 micro-meter) and Al (100 micro-meter)
monitor foils */
THK-TGT=XMG/CM**2'6';
/* '6' 650 micro-meter */
POL-TGT=0%;
ALGN-TGT=0%;
ACC=CYC;
INST-ACC=2JPNTOH'7';
/* '7' Cyclotron and Radioisotope Center */
POL-PRJ=0%;
COINC=NO;
ANT-COINC=NO;
DET-SYS=HPGE'8';
/* '8' To measure activity non-destructively */
ANL=X'9';
/* '9' ALICE-IPPE model code (A.I.Dityuk et al., 1998) */
/* Experimental Method:
- Activation
- Stacked target irradiation (Prepared by inserting Zn target
foils, Cu and Al monitor foils together in sequence)
- Gamma ray spectrometry
RCT=ZN(P,X)52MN;
DET-PARTCL=GAMMA'48';
/* '48' Delayed gamma from 52Mn (ground state) */
/*===================================================================*/
/* Descriptive Parameters */
/*===================================================================*/
\\DATA,13;
SYS-ERR=(1%'10',7%'11',5%'12');
/* '10' Uncertainty from foil thickness */
/* '11' Uncertainty from incident proton flux */
/* '12' Uncertainty from calculated detector efficiency */
STATIST-ERR=10%'13';
/* '13' Maximum uncertainty from the count rate determination of
the photo peak areas of gamma-lines (1-10%) */
ENGY-GAMMA=(744.2KEV'49',935.5KEV'50',1434.1KEV'51');
INTNSTY-GAMMA=(0.900'49',0.945'50',1.00'51');
HALF-LIFE=(5.591DAY'49',5.591DAY'50',5.591DAY'51');
/* '49' Delayed gamma from 52Mn (ground state) */
/* '50' Delayed gamma from 52Mn (ground state) */
/* '51' Delayed gamma from 52Mn (ground state) */
/*===================================================================*/
/* Data Table */
/*===================================================================*/
\DATA;
INC-ENGY-LAB DELTA-INC-ENGY-LAB XSECTN DELTA-XSECTN
(MEV) (MEV) (MB) (MB)
54.9 +-0.8 0.024 +-0.005
59.3 +-0.6 0.065 +-0.010
63.4 +-0.5 0.11 +-0.02
67.4 +-0.3 0.13 +-0.02
\END;
/*===================================================================*/
|