/* NRDF D1769 Data No.13 */
/*===================================================================*/
/* Bibliography */
/*===================================================================*/
\\BIB,13;
D#=D1769;
TITLE=/ Double-differential cross sections for the neutron
production from heavy-ion reactions at energies E/A = 290-600
MeV /;
PURPOSE=/ Systematic measurements of neutron-production cross
sections from C, Ne, and Ar projectiles having E/A = 290-600
MeV on C, Cu, and Pb targets. /;
ATH=(Y.IWATA'1', T.MURAKAMI'1', H.SATO'2', H.IWASE'2', T.NAKAMURA'2',
T.KUROSAWA'2', L.HEILBRONN'3', R.M.RONNINGEN'4', K.IEKI'5',
Y.TOZAWA'5', K.NIITA'6');
INST-ATH=(2JPNIRS'1', 2JPNTOH'2', 1USABRK'3', 1USAMSU'4', 2JPNRIK'5',
2JPNJPN'6');
/* '1' Department of Accelerator Physics and Engineering */
/* '2' Cyclotron and Radioisotope Center */
/* '4' National Superconducting Cyclotron Laboratory */
/* '5' Department of Physics */
/* '6' Research Organization for Information Science and
Technology, Tokai, Naka, Ibaraki */
REF=PR/C;
VLP=64(2001)054609;
RCTS=(C(12C,N)X, CU(12C,N)X, PB(12C,N)X, C(20NE,N)X, CU(20NE,N)X,
PB(20NE,N)X, C(40AR,N)X, CU(40AR,N)X, PB(40AR,N)X);
PHQS=(ENGY-SPEC, ANGL-DSTRN, XSECTN, TOT-XSECTN, MLT);
/*===================================================================*/
/* Experimental Conditions */
/*===================================================================*/
\\EXP,13;
/* 2002-08-01 : Compiled, Am + Sr + On */
/* 2006-07-25 : Altered, On. Heading of data error corrected.
Systematic uncertainties added. */
RTY=HEAVY-ION-RCT;
ENR=NAT;
CHM=ELM;
PHYS-FORM=SLD;
BAC=X;
POL-TGT=0%;
ALGN-TGT=0%;
ACC=SYN'7';
/* '7' Heavy Ion Medical Accelerator in Chiba (HIMAC) facility
INST-ACC=2JPNIRS;
BEAM-INTNSTY=XMA'8';
/* '8' A few times 10e4-10e5 particles per pulse */
POL-PRJ=0%;
DET-PARTCL=N;
COINC=NO;
ANT-COINC=NO;
DET-SYS=(SCT'9',SCT'10',TOF);
/* '9' NE102A plastic scintillator */
/* '10' NE213 liquid scintillator */
ERS-DET=XKEV'11';
/* '11' The energy resolutions are shown in Table I in reference.
/* Experimental Method:
- Time-of-flight
RCT=CU(12C,N)X;
PHQ=ENGY-SPEC;
THK-TGT=4470MG/CM**2;
INC-ENGY-LAB=290.0MEV/A;
ANL=X'49';
/* '49' Moving-source model, QMD and HIC */
/*===================================================================*/
/* Descriptive Parameters */
/*===================================================================*/
\\DATA,13;
SYS-ERR=10%'12';
/* '12' Uncertainty in detection efficiency */
INC-ENGY-LAB=290.0MEV/A;
SYS-ERR=2.5%'50';
/* '50' Uncertainty in target thickness */
THTL=60DEG;
/*===================================================================*/
/* Data Table */
/*===================================================================*/
\DATA;
ENGY-EMT-LAB DSIGMA/DOMEGA/DE DELTA-DSIGMA/DOMEGA/DE'51'
(MEV) (MB/SR/MEV) (MB/SR/MEV)
5 35.2 +-5.3
6 23.9 +-4.4
7 19.7 +-4.4
8 18.3 +-3.6
9 16.9 +-2.9
10 12.7 +-3.5
15 6.90 +-0.69
25 4.64 +-0.75
35 3.66 +-0.80
45 3.94 +-0.65
55 3.52 +-0.73
65 4.22 +-0.67
75 3.38 +-0.73
85 3.52 +-0.58
95 2.96 +-0.64
105 2.81 +-0.62
125 3.45 +-0.41
145 1.97 +-0.33
165 1.41 +-0.30
185 0.985 +-0.288
205 0.844 +-0.162
235 0.516 +-0.154
265 0.141 +-0.173
295 0.141 +-0.055
325 0.141 +-0.050
365 -7.04e-02 +-8.46e-02
405 0.00e+00 +-8.70e-02
465 0.00e+00 +-1.48e-02
525 0.00e+00 +-7.07e-03
605 -3.52e-02 +-4.45e-02
725 1.17e-02 +-6.18e-03
885 8.80e-03 +-4.78e-03
1085 7.04e-03 +-4.00e-03
1285 7.04e-03 +-5.04e-03
1485 7.04e-03 +-4.09e-03
1685 7.04e-03 +-4.42e-03
1885 0.00e+00 +-2.21e-03
\END;
/*===================================================================*/
|