/* NRDF D1769 Data No.12 */
/*===================================================================*/
/* Bibliography */
/*===================================================================*/
\\BIB,12;
D#=D1769;
TITLE=/ Double-differential cross sections for the neutron
production from heavy-ion reactions at energies E/A = 290-600
MeV /;
PURPOSE=/ Systematic measurements of neutron-production cross
sections from C, Ne, and Ar projectiles having E/A = 290-600
MeV on C, Cu, and Pb targets. /;
ATH=(Y.IWATA'1', T.MURAKAMI'1', H.SATO'2', H.IWASE'2', T.NAKAMURA'2',
T.KUROSAWA'2', L.HEILBRONN'3', R.M.RONNINGEN'4', K.IEKI'5',
Y.TOZAWA'5', K.NIITA'6');
INST-ATH=(2JPNIRS'1', 2JPNTOH'2', 1USABRK'3', 1USAMSU'4', 2JPNRIK'5',
2JPNJPN'6');
/* '1' Department of Accelerator Physics and Engineering */
/* '2' Cyclotron and Radioisotope Center */
/* '4' National Superconducting Cyclotron Laboratory */
/* '5' Department of Physics */
/* '6' Research Organization for Information Science and
Technology, Tokai, Naka, Ibaraki */
REF=PR/C;
VLP=64(2001)054609;
RCTS=(C(12C,N)X, CU(12C,N)X, PB(12C,N)X, C(20NE,N)X, CU(20NE,N)X,
PB(20NE,N)X, C(40AR,N)X, CU(40AR,N)X, PB(40AR,N)X);
PHQS=(ENGY-SPEC, ANGL-DSTRN, XSECTN, TOT-XSECTN, MLT);
/*===================================================================*/
/* Experimental Conditions */
/*===================================================================*/
\\EXP,12;
/* 2002-08-01 : Compiled, Am + Sr + On */
/* 2006-07-25 : Altered, On. Heading of data error corrected.
Systematic uncertainties added. */
RTY=HEAVY-ION-RCT;
ENR=NAT;
CHM=ELM;
PHYS-FORM=SLD;
BAC=X;
POL-TGT=0%;
ALGN-TGT=0%;
ACC=SYN'7';
/* '7' Heavy Ion Medical Accelerator in Chiba (HIMAC) facility
INST-ACC=2JPNIRS;
BEAM-INTNSTY=XMA'8';
/* '8' A few times 10e4-10e5 particles per pulse */
POL-PRJ=0%;
DET-PARTCL=N;
COINC=NO;
ANT-COINC=NO;
DET-SYS=(SCT'9',SCT'10',TOF);
/* '9' NE102A plastic scintillator */
/* '10' NE213 liquid scintillator */
ERS-DET=XKEV'11';
/* '11' The energy resolutions are shown in Table I in reference.
/* Experimental Method:
- Time-of-flight
RCT=CU(12C,N)X;
PHQ=ENGY-SPEC;
THK-TGT=4470MG/CM**2;
INC-ENGY-LAB=290.0MEV/A;
ANL=X'46';
/* '46' Moving-source model, QMD and HIC */
/*===================================================================*/
/* Descriptive Parameters */
/*===================================================================*/
\\DATA,12;
SYS-ERR=10%'12';
/* '12' Uncertainty in detection efficiency */
INC-ENGY-LAB=290.0MEV/A;
SYS-ERR=2.5%'47';
/* '47' Uncertainty in target thickness */
THTL=40DEG;
/*===================================================================*/
/* Data Table */
/*===================================================================*/
\DATA;
ENGY-EMT-LAB DSIGMA/DOMEGA/DE DELTA-DSIGMA/DOMEGA/DE'48'
(MEV) (MB/SR/MEV) (MB/SR/MEV)
5 40.3 +-8.2
6 31.1 +-7.0
7 12.8 +-6.8
8 22.0 +-5.7
9 23.8 +-5.0
10 18.3 +-4.4
15 9.52 +-1.09
25 6.04 +-1.05
35 6.41 +-1.15
45 4.94 +-1.05
55 4.94 +-1.22
65 4.39 +-1.15
75 5.12 +-1.42
85 5.86 +-1.03
95 5.67 +-1.18
105 3.66 +-1.10
125 6.50 +-0.69
145 4.30 +-0.57
165 4.12 +-0.49
185 3.02 +-0.41
205 3.02 +-0.36
235 2.56 +-0.29
265 1.10 +-0.23
295 0.549 +-0.194
325 0.671 +-0.135
365 0.275 +-0.079
405 4.58e-02 +-3.64e-02
465 0.153 +-0.048
525 0.00e+00 +-6.55e-03
605 0.00e+00 +-4.99e-03
725 0.00e+00 +-7.04e-03
885 1.14e-02 +-6.84e-03
1085 9.15e-03 +-7.33e-03
1285 9.15e-03 +-5.72e-03
1485 9.15e-03 +-4.97e-03
1685 0.00e+00 +-4.25e-03
1885 0.00e+00 +-2.73e-03
\END;
/*===================================================================*/
|