/* NRDF D1849 Data No.11 */
/*===================================================================*/
/* Bibliography */
/*===================================================================*/
\\BIB,11;
D#=D1849;
TITLE=/Some evidence for neutron pick-up from the interior core
through the (p,d) reaction/;
ATH=(T.ISHIMATSU'1', S.HAYASHIBE'1', N.KAWAMURA'1', T.AWAYA'2',
H.OHMURA'2', Y.NAKAJIMA'3', S.MITARAI'3');
INST-ATH=(2JPNTOH'1', 2JPNTOK'2', 2JPNKYU'3');
/* '1' Department of Physics */
/* '2' Department of Physics */
/* '3' Department of Physics */
REF=NP/A;
VLP=185(1972)273;
RCTS=(100MO(P,D)99MO, 94MO(P,D)93MO, 98MO(P,D)97MO);
PHQS=ANGL-DSTRN;
/*===================================================================*/
/* Experimental Conditions */
/*===================================================================*/
\\EXP,11;
/* 2003-10-31 : Converted, Data converted from EXFOR O0586 */
PHQ=ANGL-DSTRN;
CHM=ELM;
PHYS-FORM=SLD'4';
/* '4' Metallic foils */
POL-TGT=0%;
ALGN-TGT=0%;
ACC=SYNCYC;
INST-ACC=2JPNINS;
INC-ENGY-LAB=52MEV;
POL-PRJ=0%;
DET-PARTCL=D;
COINC=NO;
ANT-COINC=NO;
DET-SYS=(MAG'5',PROP-CNTR'6',PLST-SCT);
/* '5' Broad-range magnetic spectrometer [K.Yagi et al., Nucl.
Instr. 52(1967)29] */
/* '6' 200 proportional counters along the focal plane followed by
a plastic scintillation counter with 6 phototubes */
/* Experimental Method:
- Pulse-height discrimination (Aluminium foils placed in tront of
proportional counters and a pulse-height discriminator for the
outputs from the scintillation counters allowed the elimination
of triton backgrounds from deuteron spectra.)
RCT=94MO(P,D)93MO;
ENR=93.9%;
THK-TGT=2.92MG/CM**2;
/*===================================================================*/
/* Descriptive Parameters */
/*===================================================================*/
\\DATA,11;
INC-ENGY-LAB=52MEV;
SYS-ERR=(10%'54',X%'55');
/* '54' Uncertainty in the solid angle of spectrometer */
/* '55' Uncertainties in the absolute cross sections are
estimated to be less than +-20%. */
EMT=D;
RSD=93MO;
EXC-ENGY=3.18MEV;
DELTA-EXC-ENGY=0.02MEV;
J-PTY=3/2-;
DELTA-THTL=0.23DEG'56';
/* '56' Data-point reader uncertainty */
DELTA-DSIGMA/DOMEGA=1.6%'57';
/* '57' Data-point reader uncertainty */
/*===================================================================*/
/* Data Table */
/*===================================================================*/
\DATA;
THTL DSIGMA/DOMEGA DELTA-DSIGMA/DOMEGA'58'
(DEG) (MB/SR) (%)
4.63 2.06 +-X
6.89 2.71 +-X
9.61 2.29 +-X
12.16 1.546 +-X
14.7 0.958 +-X
17.25 0.728 +-2.5
19.83 0.809 +-1.8
21.76 0.879 +-X
24.16 0.761 +-X
27.5 0.444 +-1.8
30.2 0.247 +-1.8
33.58 0.317 +-X
36.15 0.321 +-3.
39.36 0.32 +-2.8
42.72 0.255 +-4.
45.43 0.174 +-5.
48.62 0.116 +-5.
52.79 0.117 +-9.
56.64 0.106 +-5.
\END;
/*===================================================================*/
|