|
| /*===================================================================*/
/* NRDF D1809 Data No.11 */
/*===================================================================*/
/* Bibliography */
/*===================================================================*/
\\BIB,11;
D#=D1809;
TITLE=/Spectral measurements of neutrons, protons, deuterons and
tritons produced by 100 MeV/nucleon He bombardment/;
PURPOSE=/To present the angular-energy distributions of neutrons,
protons, deuterons and tritons produced from thick carbon,
aluminum, copper and lead targets bombarded by 100 MeV/nucleon
helium ion. /;
ATH=(T.KUROSAWA'1', T.NAKAMURA'1', N.NAKAO'2', T.SHIBATA'3',
Y.UWAMINO'4', A.FUKUMURA'5');
INST-ATH=(2JPNTOH'1', 2JPNKEK'2', 2JPNKEK'3', 2JPNIPC'4', 2JPNIRS'5');
/* '1' Cyclotron and Radioisotope Center */
/* '2' Tanashi Branch */
REF=NIM/A;
VLP=430(1999)400;
RCTS=(12C(ALPHA,P)X, 27AL(ALPHA,P)X, CU(ALPHA,P)X, PB(ALPHA,P)X,
12C(ALPHA,D)X, 27AL(ALPHA,D)X, CU(ALPHA,D)X, PB(ALPHA,D)X,
12C(ALPHA,T)X, 27AL(ALPHA,T)X, CU(ALPHA,T)X, PB(ALPHA,T)X);
PHQS=ENGY-SPEC'6';
/* '6' Double differential thick target yield */
/*===================================================================*/
/* Experimental Conditions */
/*===================================================================*/
\\EXP,11;
/* 2003-09-13 : Compiled */
PHQ=ENGY-SPEC'7';
/* '7' Double differential thick target yield */
ENR=X%;
CHM=ELM;
PHYS-FORM=SLD;
POL-TGT=0%;
ALGN-TGT=0%;
ACC=SYN'8';
/* '8' Heavy Ion Medical Accelerator in Chiba (HIMAC) */
INST-ACC=2JPNIRS;
INC-ENGY-LAB=100MEV/A;
POL-PRJ=0%;
COINC=NO;
ANT-COINC=NO;
DET-SYS=(SCT'9',SCT'10',TOF'11',EDE'12');
/* '9' Plastic scintillator (NE102A) was used as the delta-E
counter, ToF start signal detector, and incident projectile
counter */
/* '10' Liquid scintillator (NE213) was used as the E counter */
/* '11' To measure the energy of outgoing neutrons, protons,
deuterons and tritons */
/* '12' To eliminate charged particles */
ANL=MONTE-MTHD'13';
/* '13' LAHET Monte Carlo Code System, LCS [R.E. Prael, H.
Lichtenstein, LA-UR-89-3014, Los Alamos National Laboratory,
1989.] */
/* Experimental Method:
- Time-of-flight (To measure the energy of outgoing neutrons,
protons, deuterons and tritons)
- Particle identification by 'E/Delta E' measurement (To
eliminate charged particles)
RCT=27AL(ALPHA,P)X;
THK-TGT=10800MG/CM**2;
DET-PARTCL=P;
/*===================================================================*/
/* Descriptive Parameters */
/*===================================================================*/
\\DATA,11;
INC-ENGY-LAB=100MEV/A;
SYS-ERR=(<3%'78',<1%'79',<1%'80');
/* '78' Uncertainty in the number of accepted beam particles
incident on the target is estimated to be less than 3%. */
/* '79' Uncertainty in the solid angle for the thickest carbon
target, which has the maximum uncertainty, is less than 1%. */
/* '80' Uncertainty of charged particle detection efficiency is
estimated to be 1%, considering a small fraction of the slant
incidence of a particle onto the detector. */
STATIST-ERR=X%'81';
/* '81' The statistical uncertainties vary from 2-5% in the low
to medium energy (5-50 MeV) region of the spectra and increase
to about 30% at the highest energies. */
EMT=P;
THTL=60DEG;
DELTA-DN/DOMEGA/DE=<4%'82';
/* '82' Total normalization uncertainty */
/*===================================================================*/
/* Data Table */
/*===================================================================*/
\DATA;
ENGY-EMT-LAB-MIN ENGY-EMT-LAB-MAX DN/DOMEGA/DE'83'
(MEV) (MEV) (1/SR/MEV/PARTCL)
21.862 24.456 5.9994e-07
24.456 27.177 1.0489e-05
27.177 30.388 1.3364e-05
30.388 33.696 1.4483e-05
33.696 37.587 1.1734e-05
37.587 42.211 8.6048e-06
42.211 46.907 7.1828e-06
46.907 52.456 5.2055e-06
52.456 59.085 2.4265e-06
59.085 65.656 1.8165e-06
65.656 73.433 9.5636e-07
73.433 82.745 3.9009e-07
82.745 91.598 3.3215e-07
91.598 102.03 9.9445e-08
102.03 114.48 4.1703e-08
\END;
/*===================================================================*/
|