/* NRDF D1434 Data No.10 */
/*===================================================================*/
/* Bibliography */
/*===================================================================*/
\\BIB,10;
D#=D1434;
TITLE=/Nuclear structure of even lead isotopes by the (p,t) reaction/;
ATH=(M.TAKAHASHI'1', T.MURAKAMI'1', S.MORITA'1', H.ORIHARA'2',
Y.ISHIZAKI'3', H.YAMAGUCHI'4');
INST-ATH=(2JPNTOH'1', 2JPNTOH'2', 2JPNINS'3', 2JPNTKS'4');
/* '1' Department of Physics */
/* '2' Cyclotron and Radioisotope Center */
/* '3' Institute for Nuclear Study */
/* '4' Faculty of General Education */
REF=PR/C;
VLP=27(1983)1454;
RCTS=(208PB(P,T)206PB, 206PB(P,T)204PB, 204PB(P,T)202PB);
PHQS=ANGL-DSTRN;
/*===================================================================*/
/* Experimental Conditions */
/*===================================================================*/
\\EXP,10;
/* 2003-10-24 : Converted, Data converted to EXFOR E1434 and EXFOR
O0685 */
PHQ=ANGL-DSTRN;
ENR=>99%;
POL-TGT=0%;
ALGN-TGT=0%;
ACC=SYNCYC;
INST-ACC=2JPNINS;
INC-ENGY-LAB=51.9MEV;
POL-PRJ=0%;
DET-PARTCL=T;
COINC=NO;
ANT-COINC=NO;
DET-SYS=(MAG'5',PROP-CNTR'6',SCT);
/* '5' To analyze triton momentum */
/* '6' Array of 200 proportional counters serve as position
detectors. They form counter telescopes in combination with
scintillation counters. */
ERS-DET=[90KEV'7';
/* '7' Overall energy resolution for the tritons of interest */
ANL=DWBA'8';
/* '8' Zero-range DWBA approximation (code DWUCK-4, [W.A.Lanford
and J.B.McGrory, Michigan State University Cyclotron Laboratory
Report No.MSUCL-81, 1973 (unpublished); Phys. Lett.
45B(1973)283]) */
RCT=206PB(P,T)204PB;
CHM=ELM;
PHYS-FORM=SLD'49';
/* '49' Metallic foil */
THK-TGT=5MG/CM**2;
/*===================================================================*/
/* Descriptive Parameters */
/*===================================================================*/
\\DATA,10;
INC-ENGY-LAB=51.9MEV;
SYS-ERR=<20%'50';
/* '50' Error of the absolute cross section of the ground state
transition is estimated to be less than 20%, where the main
part comes from the uncertainty of the solid angle of each
counter on the focal plane of the magnetic spectrograph. */
EMT=T;
RSD=204PB;
EXC-ENGY=1.7MEV;
J-PTY=2+;
DELTA-THTC=0.25DEG'51';
/* '51' Data-point reader uncertainty */
DELTA-DSIGMA/DOMEGA=1.9%'52';
/* '52' Data-point reader uncertainty */
/*===================================================================*/
/* Data Table */
/*===================================================================*/
\DATA;
THTC DSIGMA/DOMEGA DELTA-DSIGMA/DOMEGA'53'
(DEG) (UB/SR) (%)
5.37 16.2 +-X
8.23 19.5 +-X
10.02 21.2 +-X
13.07 17.4 +-X
15.41 15.11 +-X
18.11 11.49 +-X
20.08 10.23 +-X
22.78 8.76 +-X
25.3 7.02 +-X
28. 5.41 +-2.2
37.88 3.1 +-13.
43.09 1.8 +-12.
47.75 2.14 +-11.
52.59 1.84 +-13.
\END;
/*===================================================================*/
|