/* NRDF D2019 Data No.1 */
/*===================================================================*/
/* Bibliography */
/*===================================================================*/
\\BIB,1;
D#=D2019;
TITLE=/ Heavy-ion reactions of Cu with 135 MeV/nucleon 12C /;
ATH=(Y.K.KIM'1', J.C.KIM'1', C.-B.MOON'2', S.Y.CHO'3', Y.H.CHUNG'4',
Y.OHKUBO'5');
INST-ATH=(3KORNSU'1', 3KORKOR'2', 3KORYON'3', 3KORKOR'4',
2JPNIPC'5');
/* '1' Department of Physics */
/* '2' Department of Physics, Hoseo University, Chonan */
/* '3' Department of Industrial Hygiene */
/* '4' Department of Chemistry, Hallym University, Chooncheon */
/* '5' Radiochemistry Laboratory */
REF=NP/A;
VLP=578(1994)621;
RCTS=CU(12C,X)X;
PHQS=XSECTN;
/*===================================================================*/
/* Experimental Conditions */
/*===================================================================*/
\\EXP,1;
/* 2006-12-20 : Compiled, K.Tsubakihara + N.Otuka */
/* Related references
- U.Reus et al., AND, 29(1983)193.
Reference from which data were used (Decay data)
PHQ=XSECTN;
/* Additional results shown but not compiled
- Range of recoils measured (Forward range and
forward-to-backward ratio)
CHM=ELM;
PHYS-FORM=SLD;
THK-TGT=23.7MG/CM**2'6';
/* '6' Surrounded by 10.5 mg/cm2-thick Mylar catcher foils */
POL-TGT=0%;
ALGN-TGT=0%;
ACC=CYC;
INST-ACC=2JPNIPC'7';
/* '7' RIKEN Accelerator Research Facility */
INC-ENGY-LAB=134.5MEV/A;
DELTA-INC-ENGY-LAB=1MEV/A;
BEAM-INTNSTY=35NA'8';
/* '8' +-10 nA */
POL-PRJ=0%;
DET-PARTCL=GAMMA'9';
/* '9' Decay data not given */
COINC=NO;
ANT-COINC=NO;
DET-SYS=GE'10';
/* '10' To measure gamma-ray of separated foils */
/* Experimental Method:
- Activation (Irradiated for 10 min for shout half-life (<24 h)
nuclides and for 2 hours (for longer half-life nuclides))
- Gamma ray spectrometry
/* Data given are weighted average of separate determinations
(short/long irradiations, several gamma-rays) */
RCT=CU(12C,X)X'13';
/* '13' See DATA section for atomic number (Z) and mass number
(A) of products */
/*===================================================================*/
/* Descriptive Parameters */
/*===================================================================*/
\\DATA,1;
INC-ENGY-LAB=134.5MEV/A;
DELTA-INC-ENGY-LAB=1MEV/A;
SYS-ERR=(5%'11',5%'12');
/* '11' Uncertainty in detector-efficiency calibration */
/* '12' Uncertainty in single determination of single gamma-ray
/*===================================================================*/
/* Data Table */
/*===================================================================*/
\DATA;
Z A ISOMER SIGMA',14' DELTA-SIGMA',15'
(NODIM) (NODIM) (NODIM) (MB) (MB)
11. 22 X 3.42 +-0.38
11. 24 X 5.59 +-0.45
12. 27 X 2.58 +-0.21
12. 28 X 0.56 +-0.05
13. 29 X 3.70 +-0.41
17. 34 1 1.01 +-0.11
17. 38 X 2.55 +-0.28
17. 39 X 0.76 +-0.08
18. 41 X 1.23 +-0.14
19. 43 X 2.02 +-0.16
19. 44 X 0.52 +-0.06
20. 47 X 0.09 +-0.01
21. 43 X 4.52 +-0.50
23. 48 X 19.7 +-1.2
24. 48 X 0.51 +-0.04
24. 49 X 5.41 +-0.43
24. 51 X 38.3 +-4.2
25. 52 1 3.66 +-0.42
25. 56 X 5.66 +-0.45
26. 53 X 2.68 +-0.29
26. 59 X 2.85 +-0.23
27. 55 X 2.18 +-0.18
27. 56 X 14.3 +-0.9
27. 57 X 45.7 +-5.0
27. 61 X 7.21 +-0.79
27. 62 1 0.90 +-0.07
28. 57 X 1.60 +-0.18
29. 60 X 6.23 +-0.50
29. 61 X 23.4 +-1.4
30. 62 X 1.37 +-0.09
30. 63 X 2.07 +-0.23
30. 65 X 1.23 +-0.14
\END;
/*===================================================================*/
|