/* NRDF D1722 Data No.1 */
/*===================================================================*/
/* Bibliography */
/*===================================================================*/
\\BIB,1;
D#=D1722;
TITLE=/ Reaction mechanism and characteristics of T20 in d+3He
backward elastic scattering at intermediate energies /;
ATH=(M.TANIFUJI'1', S.ISHIKAWA'1', Y.ISERI'2', T.UESAKA'3',
N.SAKAMOTO'3', Y.SATOU'3', K.ITOH'3', H.SAKAI'3,4', A.TAMII'4',
T.OHNISHI'4', K.SEKIGUCHI'4', K.YAKO'4', S.SAKODA'4',
H.OKAMURA'5', K.SUDA'5', T.WAKASA'6');
INST-ATH=(2JPNHOS'1', 2JPNJPN'2', 2JPNIPC'3', 2JPNTOK'4', 2JPNSUU'5',
2JPNRCN'6');
/* '1' Department of Physics */
/* '2' Department of Physics, Chiba-Keizai College, Chiba */
/* '4' Department of Physics */
/* '5' Department of Physics */
REF=PR/C;
VLP=61(2000)024602;
RCTS=D(3HE,3HE)D;
PHQS=(ANGL-DSTRN, TNSR-ANALPW'7');
/* '7' T(20) */
/*===================================================================*/
/* Experimental Conditions */
/*===================================================================*/
\\EXP,1;
/* 2002-09-05 : Converted, Data converted to EXFOR E1722 */
/* 2004-11-25 : Altered, INSTITUTE, REFERENCE and heading of
systematic error corrected */
RTY=(ELA-SCATT,POL-RCT);
ENR=X%;
CHM=ELM;
PHYS-FORM=GAS;
THK-TGT=XMG/CM**2'8';
/* '8' The size of target was 13mm(20mm) wide, 15mm(20mm)high, and
20mm(10mm)thick in the case of 270MeV(140,200MeV) measurement.
The gas pressure is approximately 1 atm which was measured with
Baratron gauge. */
POL-TGT=0%;
ALGN-TGT=0%;
ACC=CYC;
INST-ACC=2JPNIPC;
INC-ENGY-LAB=(140MEV, 200MEV, 270MEV);
POL-PRJ=60[80%;
ION-SOURCE=/ Polarized ion source (High-Intensity polarized ion source
[H.Okamura et al., in polarized ion source and polarized
gas targets, edited by L.W.Anderson and Willy Haeberli,
AIP Conf.Proc.No.293(AIP, New York, 1994), P.84]) /;
DET-PARTCL=3HE;
COINC=NO;
ANT-COINC=NO;
DET-SYS=(MAG'9',MWDC,SCT'10');
/* '9' SMART [T.Ichihara et al., Nucl.Phys.A569(1994)287c]. */
/* '10' Plastic scintillator */
MONTR-RCT=/ , The beam polarization was measured with a polarimeter
based on the d+p elastic scattering after acceleration to
140, 200, and 270MeV. /;
ANL=PWIA;
RCT=D(3HE,3HE)D;
PHQ=ANGL-DSTRN;
/*===================================================================*/
/* Descriptive Parameters */
/*===================================================================*/
\\DATA,1;
EMT=3HE;
THTL=0[1.4DEG;
DELTA-DSIGMA/DOMEGA=10%'11';
/* '11' Uncertainties mainly due to beam intensity and target
thickness */
/*===================================================================*/
/* Data Table */
/*===================================================================*/
\DATA;
INC-ENGY-LAB DSIGMA/DOMEGA DELTA-DSIGMA/DOMEGA'12'
(MEV) (MB/SR) (MB/SR)
140 16.3 +-0.1
200 8.56 +-0.03
270 0.97 +-0.08
\END;
/*===================================================================*/
|