|
| /*===================================================================*/
/* NRDF D1586 Data No.1 */
/*===================================================================*/
/* Bibliography */
/*===================================================================*/
\\BIB,1;
D#=D1586;
TITLE=/ Single-particle states in 59Ni with 58Ni(d,p)59Ni reaction
at 56 MeV and neutron-bound-state complex potentials /;
PURPOSE=/ To measure the cross sections and analyzing powers /;
ATH=(O.IWAMOTO'1', A.NOHTOMI'1', Y.UOZUMI'1', T.SAKAE'1', M.MATOBA'1',
M.NAKANO'2', T.MAKI'2', N.KOORI'3');
INST-ATH=(2JPNKYU'1', 2JPNKIT'2', 2JPNTKS'3');
/* '1' Department of Nuclear Engineering */
/* '2' School of Nursing and Technology */
/* '3' Faculty of Integrated Arts and Sciences */
REF=NP/A;
VLP=576(1994)387;
RCTS=58NI(D,P)59NI;
PHQS=(SPEC-FCTR, ANGL-DSTRN, VCTR-ANALPW, SPEC-FCTR'4');
/* '4' Sum of spectroscopic factor */
/*===================================================================*/
/* Experimental Conditions */
/*===================================================================*/
\\EXP,1;
/* 2005-09-24 : Converted, Sr + On. Converted to EXFOR E1586 */
/* 2005-11-07 : Altered, At + Kc + Sr. Re-digitized */
/* Related references
- N.Matsuoka et al., NP/A, 455(1986)413.
ENR=99.89%;
CHM=ELM;
PHYS-FORM=SLD;
THK-TGT=0.473MG/CM**2;
POL-TGT=0%;
ALGN-TGT=0%;
ACC=CYC'5';
/* '5' Isochronous cyclotron, AVF cyclotron */
INST-ACC=2JPNRCN;
INC-ENGY-LAB=56MEV;
POL-PRJ=[50%;
DET-PARTCL=P;
COINC=NO;
ANT-COINC=NO;
DET-SYS=MAG'6';
/* '6' Magnetic spectrograph RAIDEN [H.Ikegami, et al. Nucl.
Instr. Meth. 175(1980)33] with the focal-plane detector system
KYUSHYU [M.Matoba, et al. Nucl. Instr. Meth. 180(1981)419] */
ERS-DET=45KEV;
ANL=DWBA'7';
/* '7' Code DWUCK [P.D.Kunz, code DWUCK, University of Colorado
(unpublished)] */
RCT=58NI(D,P)59NI;
PHQ=SPEC-FCTR;
/*===================================================================*/
/* Descriptive Parameters */
/*===================================================================*/
\\DATA,1;
INC-ENGY-LAB=56MEV;
SYS-ERR=X%'8';
/* '8' Uncertainty in run-to-run variations of the integrated beam
current are on the order of a few percent. */
EMT=P;
/*===================================================================*/
/* Data Table */
/*===================================================================*/
\DATA;
EXC-ENGY TRNSF-L TRNSF-J'9' SPEC-FCTR
(MEV) (NODIM) (NODIM) (NODIM)
0.000 1 3/2 0.537
0.340 3 5/2 0.687
0.463 1 1/2 0.538
0.879 1 3/2 0.073
1.196 3? 5/2? 0.015
1.305 1 1/2 0.339
1.682 3 5/2 0.104
1.949 3 7/2 0.012
2.414 1? 3/2? 0.013
2.626 3 7/2 0.014
2.685 3 5/2 0.022
3.059 4 9/2 0.381
3.298 X X X
3.448 1 3/2 0.054
3.553 2 5/2 0.019
3.651 3 5/2 0.021
3.863 1 3/2? 0.054
4.037 1 3/2? 0.034
4.160 1 3/2? 0.068
4.295 1? 1/2? 0.109
X 4? 9/2? 0.025
4.505 2 5/2 0.154
4.689 4 9/2 0.037
4.817 2 5/2 0.033
4.965 1 3/2? 0.071
5.155 0 1/2 0.124
5.248 2 5/2 0.017
5.439 4? 9/2? 0.061
X 2? 5/2? 0.051
5.541 0 1/2 0.109
5.603 1? X X
5.694 0 1/2 0.127
5.786 1? X X
5.908 2? 5/2? 0.048
6.035 X X X
6.134 1? X X
6.206 2 5/2 0.023
6.281 2 5/2? 0.049
6.375 0? 1/2? 0.213
6.467 2? X X
6.557 X X X
6.617 2 X X
6.692 2? X X
6.800 2? X X
6.909 2 X X
7.014 2 X X
7.116 2? X X
7.192 2? X X
7.347 2 5/2 0.044
7.427 2 X X
7.533 2 X X
7.623 2? X X
\END;
/*===================================================================*/
|